Panasonic KV-S3105C Operating Instructions - Page 20

Not detect, Detect, Buzzer, Low Sensitivity, Double feed detection, Setting the Double Feed detector

Page 20 highlights

Display Panel Instructions 14 Double feed detection 14 . Doub l e Feed Ho s t 15 Setting the "Double Feed" detector action 15 . Doub l e Feed Ac t i on Ho s t 16 Setting the double feed detector sensitivity 16 . Doub l e Feed Sen s . Ho s t Host Not detect Detect If set to "Detect", the scanner will detect double feeding. • When scanning very important documents, confirm if the number of scanned pages displayed on the LCD matches the number of actual pages. Host Stop Buzzer Host: The scanner will act in response to commands from the host computer. Stop: The scanner will display double feeding error and stop when it detects double feeding. Buzzer: When the scanner detects double feeding, it will sound a buzzer, the power indicator will light red and it will continue scanning. After completing scanning, the scanner will display double feeding warning. Even if this buzzer is set to "OFF" in "Setting the buzzer" (see page 25), it will still ring. Host Low Sensitivity Normal Sensitivity High sensitivity Low Sensitivity: The double feed detector's sensitivity will be low. Set this when there is an error for no double feeding. High Sensitivity: The double feed detector's sensitivity will be high. Set this when there is no error for double feeding. • Thick, creased, or edited documents with correction fluid as well as documents with holes near the center may give you false double feed warning. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

Display Panel Instructions
20
• Thick, creased, or edited documents with correction fluid as well as documents with holes near the center may
give you false double feed warning.
14
Double feed detection
If set to “Detect”, the scanner will detect double feeding.
• When scanning very important documents, confirm if the
number of scanned pages displayed on the LCD matches
the number of actual pages.
15
Setting the “Double Feed” detector
action
Host
:
The scanner will act in response to commands from
the host computer.
Stop
:
The scanner will display double feeding error and
stop when it detects double feeding.
Buzzer
:
When the scanner detects double feeding, it will
sound a buzzer, the power indicator will light red and
it will continue scanning.
After completing scanning, the scanner will display
double feeding warning.
Even if this buzzer is set to “OFF” in “Setting the
buzzer” (see
page 25
), it will still ring.
16
Setting the double feed detector
sensitivity
Low Sensitivity:
The double feed detector’s sensitivity will be
low. Set this when there is an error for no
double feeding.
High Sensitivity: The double feed detector’s sensitivity will be
high. Set this when there is no error for dou-
ble feeding.
14.Double
Feed
Host
Not detect
Host
Detect
15.Double
Feed
Act
ion
Host
Stop
Host
Buzzer
16.Double
Feed
Sens.
Host
Low Sensitivity
Host
High sensitivity
Normal Sensitivity