    ® Upper Arm Blood Pressure Monitor Monitor de presi6n arterial de brazo Operating Instructions Instrucciones de funcionamiento Model No. EW3122 Modelo No. EW3122 For questions or assistance with your blood pressure monitor, call us at 1-800-338-0552. • • Panasonic Consumer Electronics Company
  • Panasonic ew3122s | EW3122 User Guide - Page 2
    for the device 27 Troubleshooting 28 1 Introduction Thank you for purchasing the Panasonic Upper Arm Blood Pressure Monitor EW3122. Measuring your own blood pressure is an important way of monitoring your health. High blood pressure (hypertension) is a major health problem which can be treated
  • Panasonic ew3122s | EW3122 User Guide - Page 3
    that your blood pressure is lower at home, this is not unusual. To accurately compare with your physician's reading, take your Panasonic blood pressure monitor to batteries. d. Be sure to insert batteries with correct polarity, as instructed. e. Remove batteries when they are wom out, and dispose of
  • Panasonic ew3122s | EW3122 User Guide - Page 4
    not store the unit in direct sunlight, high humidity or dust. Easily Check Your Blood Pressure Readings Against the JNC 7* Classification Blood Pressure Categories Diastolic Blood Pressure (DBP) A (mmHg) Stage 2 Hypertension e.g.: SBP 165 DBP 105 100 Stage 1 Hypertension e.g.: SBP 150 DBP
  • Panasonic ew3122s | EW3122 User Guide - Page 5
    cuff socket Display Set button Memory/Recall button 1 Tube Pressure cuff Pressure cuff plug Bottom of main body Battery cover Cover Blood pressure indicator lamps Connector (for AC adapter) Body movement indicator lamp Change button Memory/Recall button 2 On/Off Start button How to open the
  • Panasonic ew3122s | EW3122 User Guide - Page 6
    alkaline batteries (four AA-size LR6 batteries). (Measurement conditions: Room temperature 22°C (72°F); Pressurized to 170mmHg; Upper arm circumference: 30cm (11-51/64")) • When batteries other than Panasonic alkaline batteries are used, battery life may be shorter. When manganese batteries are used
  • Panasonic ew3122s | EW3122 User Guide - Page 7
    STARTING MEASUREMENTS Setting the date and time * Please be sure to set the date and time before taking the first measurement after purchasing the blood pressure monitor or after changing the batteries. • If measurements are taken without setting the date and time, the date and time will not be
  • Panasonic ew3122s | EW3122 User Guide - Page 8
    using the same upper arm in the same position at the same time every day. • Measurement values will vary according to the height of the pressure cuff. • Take measurements in the morning immediately after you wake up, when there is no urge to urinate. If this is difficult, take measurements before
  • Panasonic ew3122s | EW3122 User Guide - Page 9
    arm to the correct posture. (See p. 13.) • When body movement has been detected, the body movement indicator lamp will blink when the blood pressure reading appears. (The lamp will also blink when measurements for which movement was detected are stored and later recalled.) Body movement indicator
  • Panasonic ew3122s | EW3122 User Guide - Page 10
    , the oldest value in memory will be Panasonic B/ 3 15:30 co. nn.y... 38. ---. ,S..Y.St f$ 82 : r...... DIA. ....ag deleted and the new value will be stored. • If measurements could not be taken properly (the E mark is shown instead of the blood pressure value), measurement values cannot be stored
  • Panasonic ew3122s | EW3122 User Guide - Page 11
    previously stored measurement values will be shown in order, starting with the newest data. Panasonic . an 8/I 3 (5,313 .„..W .m .M.... ••e - IDNIM 138 ....... 82 ...= t% • The blood pressure indicator lamps will light (for approximately 6 seconds). • If your body moves during measurement, the
  • Panasonic ew3122s | EW3122 User Guide - Page 12
    button to complete the setting. To cancel the measurement notification sound: Press the Set button "1" on the top surface of the blood pressure monitor. (Notification Time 1 will blink.) • To change the setting for Notification Time 2 or 3, press the Change button "2" to display Notification Time
  • Panasonic ew3122s | EW3122 User Guide - Page 13
    6V (4 AA-size alkaline batteries) AC 100-240V 50/60Hz (when using optional AC adapter) Digital LCD Oscillometric system Blood pressure: 0 to 280mmHg Pulse rate: 30 to 160 beats per minute Blood pressure: Within ±3mmHg Pulse rate: Within ±5% 10 to 40°C (50°F to 104°F), 15 to 90% RH -20 to 60°C (-14
  • Panasonic ew3122s | EW3122 User Guide - Page 14
    posture. Because of this, when taking measurements, be sure to always take measurements under the same conditions. 0 For persons taking blood pressure medication, blood pressure may change greatly due to the effects of the medication. ® When taking 2 measurements in succession, be sure to stay
  • Panasonic ew3122s | EW3122 User Guide - Page 15
    TROUBLESHOOTING Display Remeasure mark E is displayed. 8/ 3 15:30 E Status before error Pressurization to more than 280mmHg was performed. Pressure while measurement were being taken. See pp.12and 13. If problem continues Blood pressure value is abnonnally high or low. • Posture is different for
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Panasonic®
Upper
Arm
Blood
Pressure
Monitor
Monitor
de
presi6n
arterial
de
brazo
Operating
Instructions
Instrucciones
de
funcionamiento
Model
No.
EW3122
Modelo
No.
EW3122
For
questions
or
assistance
with
your
blood
pressure
monitor,
call
us
at
1-800-338-0552.
Panasonic
Consumer
Electronics
Company
Division
of
Panasonic
Corporation
of
North
America
One
Panasonic
Way
3D-1
Secaucus,
NJ
07094
Before
operating
this
device,
please
read
these
instructions
completely
and
save
this
manual
for
future
use.
No.2
EN,SP
(7,
0
1
)
Antes
de
utilizar
este
dispositivo,
lea
completamente
estas
instrucciones
y
conserve
©
2005
Matsushita
Electric
Works,
Ltd.
All
Rights
Reserved.
Printed
in
China
este
manual
para
futura
referencia.