Pentax ist *ist Manual - Page 145
Basic Operation, Preparation, Shooting, Advanced Operations, Others
View all Pentax ist manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
143 BASIC OPERATION (PREPARATION) BASIC OPERATION (SHOOTING) ADVANCED OPERATIONS Lenses Exposure mode Restriction FA, F, A, M, S (lens Aperture-Priority only, or with auto diaphragm AE mode accessories such as auto extension tube K FA, F, A, M, S (with Aperture-Priority manual diaphragm AE mode accessories such as extension tube K Manual diaphragm Aperture-Priority lens, such as reflex AE mode lens (lens only) FA, F Soft 85mm FA Soft 28mm (lens only) Aperture-Priority AE mode All lenses Metered Manual The aperture remains wide open regardless of the aperture ring position. The shutter speed varies according to the aperture ring position, however, an exposure error may occur. Aperture value displays [F--] in the viewfinder and [AV--] on the LCD panel. Pictures can be taken with the specified aperture value, however, an exposure error may occur. Aperture value displays [F--] in the viewfinder and [AV--] on the LCD panel. Pictures can be taken with the aperture value manually specified, however, an exposure error may occur. Aperture value displays [F--] in the viewfinder and [AV--] on the LCD panel. Pictures can be taken with the specified aperture value and shutter speed, however, the built-in light meter does not operate, therefore, the exposure cannot be evaluated. Aperture value displays [F--] in the viewfinder and [AV--] on the LCD panel. OTHERS