Pioneer 504CMX Technical Manual

Pioneer 504CMX - PDP - 50" Plasma Panel Manual

Pioneer 504CMX manual content summary:

  • Pioneer 504CMX | Technical Manual - Page 1
    TECHNICAL MANUAL (Ver. 1.0) HANDWRITING DEVICE: PDK-50HW3 Supported plasma displays: PDP-504CMX PDP-503CMX PDP-50MXE1 PDP-50MXE1-S PDP-503MXE This manual provides precautions and information for installation, preparation, and handling of the handwriting device. Before installation and preparatory
  • Pioneer 504CMX | Technical Manual - Page 2
    ¶ An RS-232C connector is no longer provided. ¶ The absence of connectors on the rear panel makes it possible to use fittings for installation on sloping surfaces. 2. Power is supplied through USB bus power. ¶ The scan device is not provided with a power switch or a DC connector. ¶ An AC adapter and
  • Pioneer 504CMX | Technical Manual - Page 3
    securing two USB cables is provided on the rear panel to ensure that cables are neatly routed. ] See page 22. e) A power indicator makes it possible to check plasma display operating status. ] PDK-50HW2A f) The flash pattern of the power indicator has changed. ] See page 21. PDK-50HW3 g) The
  • Pioneer 504CMX | Technical Manual - Page 4
    the driver a) New driver (CBdrv = CBdrvU) b) New icon ] CBdrv CBdrvU c) Menu changes • Current Resolution • Resolution • Calibration • Properties • Hardware Information • Help • About • Exit Test Mode Rotation Mode Disable CBdrvU CBdrvU 0° 90° 180° 270° d) "SelfTest" information (service
  • Pioneer 504CMX | Technical Manual - Page 5
    -50HW3 ] PDK-50HW2A PDK-50HW3 g) Middle button (3-button emulation) is supported. ] See page 32. Changes in service a) Service Mode has been improved. Fixed low scan mode PDK-50HW2A ] Fixed low scan mode Fixed ultra low scan mode PDK-50HW3 b) Internal DIP switch settings have been changed
  • Pioneer 504CMX | Technical Manual - Page 6
    42 7. Q & A 43 7.1 Hardware-Related Q&A 43 7.2 Driver Software-Related Q&A 45 8. Troubleshooting 47 8.1 Plasma Display (PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S 47 8.2 Handwriting Device (PDK-50HW3 49 9. Capabilities of the Handwriting Device 50 9.1 IR Scanning System 50 9.2 Resolution 50 6
  • Pioneer 504CMX | Technical Manual - Page 7
    bolt 1 Pen stand 1 Operating Instructions 1 CD-ROM (Device driver disc 1 Driver Installation Guide 1 ¶ Specifications and appearance may change without notice. ¶ Information regarding plasma displays in this Technical Manual is limited to the PDP-504CMX. Note 1 Allow for 400 W 400 VA of power
  • Pioneer 504CMX | Technical Manual - Page 8
    1. Specifications 1.2 Accessories 1.2.1 Plasma display monitor (PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S) Check that the following accessories were supplied. Power cord Bead band x 2 Remote control unit Display stand x 2 AA (R6) batteries x 2 Cleaning cloth (for wiping front panel) Washer x 2 Hex
  • Pioneer 504CMX | Technical Manual - Page 9
    1. Specifications 1.3 Outline Drawing System weight: 48.4 kg (plasma display (PDP-504CMX) 41.0 kg plus handwriting device 7.4 kg) Materials: Front panel (frame Aluminum Corner sections Resin Base shield, corner reinforcement .... Metal plate Finish: Front panel (frame Painting (Pioneer
  • Pioneer 504CMX | Technical Manual - Page 10
    Specifications 278 758 344 PEN NORMAL PEN-NORMAL mode selector switch (in lower left corner as seen from rear) 4 20 PPEN NNORMAL Plasma display side panel mm in diameter (approx. 1.4 m long) Bottom panel of plasma display R4 9 Dimensions from right edge of 115 14 PDK-50HW3 as
  • Pioneer 504CMX | Technical Manual - Page 11
    1. Specifications 1.4 Name and Function of Parts & Pin Layout 1.4.1 Plasma display monitor (PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S) For information on the plasma display, refer to "Name and Function of Parts" in the Technical Manual supplied with the PDP-504CMX. 1.4.2 Handwriting device (PDK-50HW3)
  • Pioneer 504CMX | Technical Manual - Page 12
    Technical Manual of the plasma display. 2.2.1 List showing compatibility of standard metal fittings Model No. PDK-5001 Product TABLE TOP STAND PDK-TS01 TABLE TOP STAND PDK-5002 PDK-5012 PDK-5005 PDK-5006 PDK-5011 PDK-5013 PDK-WM01 PDK-WM02 PDK-5008 CEILING MOUNT UNIT PDP BRACKET HUNG ON WALL
  • Pioneer 504CMX | Technical Manual - Page 13
    device are the same as for the plasma display. Refer to "Special Installation" in the Technical Manual of the plasma display. ¶ Calculate the distance between the monitor and surroundings (wall, etc.) based on the maximum dimensions of the scan device. ¶ The handwriting device can be tilted
  • Pioneer 504CMX | Technical Manual - Page 14
    sunlight Normal lighting is not a problem, but installation in a location exposed to strong lighting and intense direct sunlight will make the plasma display difficult to view and make toucth screen device operation unstable. Installation in such a location will also make remote control operation
  • Pioneer 504CMX | Technical Manual - Page 15
    13. Remote control holder 14. Display stand 15. Binder assembly (speed clamp x 2, bead band x 2) 16. Wiping cloth (for screen) 17. Ground connection label 18. Cable tie 19. Screw set 20. Washer 21. Hex hole bolt 22. Operating instructions (Japanese/ English/French) 23. Warranty card 24. Polyethylene
  • Pioneer 504CMX | Technical Manual - Page 16
    (350 x 550) Warranty Card 9 Mirror Mat (1400 x 1800) vinyl tie Air Cap Sheet (150 x 100) vinyl tie No. Description 1 Pen 2 AAA (LR03) alkaline batteries 3 Replacement Tips 4 Allen Bolt 5 Pen Stand 6 Operating Instructions 7 CD-ROM (Device driver disc) 8 Driver Installation Guide 9 Packing Set 16
  • Pioneer 504CMX | Technical Manual - Page 17
    3.2 Assembly and Connections 3.2.1 Installing the handwriting device (PDK-50HW3) 3. Installation Procedures Notes: ¶ Always install the plasma display on a mobile cart before installing scan device. ¶ After installing scan device, never attempt to lift the plasma display to install on a mobile
  • Pioneer 504CMX | Technical Manual - Page 18
    scan device in place. 2 Press in the locking fixture's stopper to prevent the fixture from moving. Locking fixture Stopper 4. Attach the pen stand. Use the furnished Allen bolt to fasten the pen stand regulations or environmental public instruction's rules that apply in your country / area. 18
  • Pioneer 504CMX | Technical Manual - Page 19
    3. Installation Procedures 3.2.3 Connecting the plasma display to a computer For information on connecting the plasma display to a computer, refer to "Installation and Connections" in the Operating Instructions supplied with the plasma display. Note: Turn the power off before making or changing
  • Pioneer 504CMX | Technical Manual - Page 20
    Procedures 3.4 Adjusting the Plasma Display 3.4.1 Procedures for setting the plasma display For details, refer to the Technical Manual of the plasma display. 1. First, set the "System Settings". Set "SIGNAL FORMAT". To use 1280 x 768 (60 Hz/70 Hz) screen resolution and refresh rate, set "SIGNAL
  • Pioneer 504CMX | Technical Manual - Page 21
    Technical Manual supplied with the plasma display. 3.5 Installing the Driver 1. Install CBdrvU. Refer to "Installing the CBdrvU (Ver. 2.0) Driver" on page 25. 2. Reboot the computer. 3.6 Connecting a Scan the accompanying screen message will appear: The power indicator will flash orange, and then
  • Pioneer 504CMX | Technical Manual - Page 22
    switch on the rear of the scan device is set to "NORMAL". ("NORMAL" is the factory default.) 2. Click CBdrvU in the task tray. In the pop-up menu that appears, select "Test Mode" under "Hardware Information" to open the test window. 3. Touch the plasma display to check that only "L" under system
  • Pioneer 504CMX | Technical Manual - Page 23
    with the position of the pen tip. Pen tip Mouse cursor (screen display position) If the cursor position differs from that of the physical pen tip menu appears, left-click on "Calibration...". 3 Follow the calibration instructions that appear onscreen. Note: Input to the unit can be performed
  • Pioneer 504CMX | Technical Manual - Page 24
    used to draw images at this time. 8. Set the mode selector switch on the rear of the scan device to the mode desired by the user ("PEN" or "NORMAL"). *1 CBdrvU test display ¶ : button recognition ‡ : button operation not available *2 Example of drawing check operation Draw oblique lines across the
  • Pioneer 504CMX | Technical Manual - Page 25
    Using Software 4.1 Installing the CBdrvU (Ver. 2.0) Driver *Supplied with PDK-50HW3 4.1.1 Operating environment a) Operating environment ¶ Supported plasma displays: PDP-504CMX PDP-503CMX PDP-50MXE1 PDP-50MXE1-S PDP-503MXE ¶ Supported computers Model: IBM PC-AT or compatible CPU: Pentium
  • Pioneer 504CMX | Technical Manual - Page 26
    select "Control Panel". 3. Double instructions that appear to remove the program. ¶ To also remove the registry data, requires a utility for removing registry data. Such a utility is provided on the supplied CD-ROM (driver). 4.1.4 Changes from CBdrv Ver. 1.4 to CBdrvU Ver. 2.0 ¶ The software supports
  • Pioneer 504CMX | Technical Manual - Page 27
    CBdrvU icon in the task tray to open the pop-up menu shown below. [Overview] Current Resolution: Calibration: Property: Hardware Information: Help: About: Exit: Indicate current resolution Open a screen for adjusting pen tip and cursor position Perform pen settings Select to view test information
  • Pioneer 504CMX | Technical Manual - Page 28
    screen appears during scan device setup. (This screen closes automatically when setup completes). d) Scan device off screen This screen appears when the scan device is disconnected selected when prompted for calibration after changing the resolution and number of colors during CBdrvU operation. 28
  • Pioneer 504CMX | Technical Manual - Page 29
    the initial setup instructions for the plasma display in the section "Precautions" in this Technical Manual.) ¶ Only modes with a preset screen resolution value are enabled. Easy Setting is not available when there is no preset resolution. ¶ Adjustment of the plasma display and video card may shift
  • Pioneer 504CMX | Technical Manual - Page 30
    calibration using Detail-2, it is still possible to verify the display position and adjust the plasma display. c) Easy Setting Press the assigned hot keys to set the preset values for the screen modes that are available at current resolution. The name of the screen mode being adjusted appears at
  • Pioneer 504CMX | Technical Manual - Page 31
    . Set to enable/disable the small button on the pen and recognition of changes in resolution. Notes: ¶ Screen appearance varies with computer environment. ¶ The settings described here affect every login user. a) Double-click area Set the effective double-click range of the pen. Notes: ¶ Screen
  • Pioneer 504CMX | Technical Manual - Page 32
    /disable the small button of the pen, the 3-button mouse emulation function when small button is enabled, enable/disable recognition of changes in resolution and optimization of HTML operation. A check mark indicates that the respective function is enabled while the lack of a check mark indicates it
  • Pioneer 504CMX | Technical Manual - Page 33
    . b) Test chart display This is a service mode. Use it to adjust plasma display settings. Notes: ¶ The plasma display need not be adjusted if it has already been set up. ¶ Use the supplied remote control to adjust the plasma display. For details, refer to the Operating Instructions. ¶ Press the
  • Pioneer 504CMX | Technical Manual - Page 34
    disable CBdrvU. a) Disabling CBdrvU Checking the "Disable CBdrvU" checkbox displays the following message. Note: The pen cannot be used when CBdrvU Check driver version. Have the driver version information ready when making inquiries about the software. 4.2.7 Exit Exit CBdrvU. The scan device cannot
  • Pioneer 504CMX | Technical Manual - Page 35
    4. Installing and Using Software 4.3 Rotate 4.3.1 CBdrvU operation A video card enabling screen rotation is required for this function. a) Task tray display 1. Left-click the CBdrvU icon in the task tray to open the pop-up menu shown below. [Rotate functions] Rotate Mode: Select rotate angle. A
  • Pioneer 504CMX | Technical Manual - Page 36
    on recommended computers and video cards, consult a Pioneer dealer. b) Easy Setting Easy Setting is optimized for PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S and Microsoft Windows XP. Cursor position may slip due to due to video card adjustment or characteristics, plasma display adjustment or discrepancies
  • Pioneer 504CMX | Technical Manual - Page 37
    rotate angle to 90° in Property screen when the plasma display is to be set up in the standard setting. ¶ When the handwriting device is to be set up vertically, locate the remote control sensor at the bottom as shown below. Locate it so that the Pioneer logo appears on the left side. 37
  • Pioneer 504CMX | Technical Manual - Page 38
    mode do not provide a correct assessment. ¶ Perform the test with the scan device firmly installed in the plasma display as a correct assessment will not be obtained unless the scan device is correctly installed. b) Status displayed after pressing SelfTest button 1. When LED and Sens are normal The
  • Pioneer 504CMX | Technical Manual - Page 39
    data for each Point. Note: "ALL" may indicate a malfunction that is not caused by the specific board. Control signal lines from the test board A (LED) and optical signals lines to the The handwriting device must be reset (disconnect and connect USB cable) to switch DIP switch to service mode. 39
  • Pioneer 504CMX | Technical Manual - Page 40
    and Cleaning Periodical maintenance is recommended to improve the service life and performance of the system. In the maintenance, clean the system equipment as described in the following. a) Plasma display monitor, scan device, remote control unit and special pen Never use solvents such
  • Pioneer 504CMX | Technical Manual - Page 41
    tip becomes deformed and writing quality deteriorates, replace the tip with one of the two supplied extras. Note: Continued use of a worn pen tip may damage the display. 1. Remove the tip. 2. Insert one of the supplied replacement tips. f) Pen battery life The battery in the pen has a life of about
  • Pioneer 504CMX | Technical Manual - Page 42
    (Locked ultra low scan mode) ¶ The light emitting status of infrared LEDs can be observed in a dark room, but this depends on the camera used. ¶ The touch panel input functions do not operate in this mode. ¶ The power indicator on the device front panel blinks continuously in approximately 1 second
  • Pioneer 504CMX | Technical Manual - Page 43
    mode). The factory-setting mode is the NORMAL mode. Q: Writing on the screen using a finger will soil it. Can a glass cleaner or similar detergent be used to clean the screen? A: Basically, such detergents should not be used. Use the supplied wiping cloth to clean the plasma display. If the screen
  • Pioneer 504CMX | Technical Manual - Page 44
    problem if the installation position is between vertical and 25° downward facing. Q: How to wall-mount the system using the plasma display bracket (PDK-5005)? A: In addition to the plasma display bracket, additional wall-mount hardware is required. Q: Is it possible to use the table top stand (PDK
  • Pioneer 504CMX | Technical Manual - Page 45
    CBdrv drivers coexist? A: Yes, if they are installed in different folders. PDK-50HW3 supports only almost identical thanks to the physical specification (if they are different, the to identify the resolution of the current output to the plasma display monitor? A: Open the pop-up menu
  • Pioneer 504CMX | Technical Manual - Page 46
    of normal output to the plasma display monitor is set as the initial value, but it may be deviated slightly due to the difference in video card. If this happens, use the detailed calibration for setting. The set value is held in memory even after the next startup or resolution change. Q: Is it
  • Pioneer 504CMX | Technical Manual - Page 47
    the other devices that are connected to the plasma display. 8.1 Plasma Display (PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S) General problems Problem • No power • Unit cannot be operated. • Remote control does not operate. • Picture is cut off. • Strange color, light color, or dark, or color misalignment
  • Pioneer 504CMX | Technical Manual - Page 48
    (simplified radios) etc., or a nearby personal computer, TV, or video/ audio component. • A strong electromagnetic field may cause picture distortion and similar problems. • Normal sound of the cooling fan and internal sliding parts of the plasma display panel. Not a malfunction. • Fan is set to
  • Pioneer 504CMX | Technical Manual - Page 49
    Or resolution has been changed. • The plasma display's screen display size setting has been changed. • Driver software is not installed properly. • The plasma display's screen display position has shifted. • The plasma display's AUTO SET UP screen position adjustment has been reset. • Plasma display
  • Pioneer 504CMX | Technical Manual - Page 50
    plasma display monitor pixels (1280 x 768). 9.2 Resolution This device uses infrared beams to scan the screen vertically and horizontally to detect obstructions. The scanning pattern is automatically adjusted to improve response and accuracy of location detection. a) Low scan mode The entire panel
  • Pioneer 504CMX | Technical Manual - Page 51
    51
  • Pioneer 504CMX | Technical Manual - Page 52
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

HANDWRITING DEVICE:
PDK-50HW3
Supported plasma displays:
PDP-504CMX
PDP-503CMX
PDP-50MXE1
PDP-50MXE1-S
PDP-503MXE
ABOUT MOUNTING/INSTALLATION
÷
This product is sold under the assumption that
installation will be performed by experienced,
qualified experts. Refer all mounting and installation
work to qualified personnel, or consult the nearest
PIONEER dealer for assistance.
÷
We accept no responsibility for accident or loss
resulting from failure to select an appropriate
installation site, or for those occurring during
assembly, installation, mounting, or operation of this
product, or resulting from modifications made to this
product, or from natural disasters.
PRECAUTIONS:
We accept no responsibility for losses resulting from the use of parts other than those supplied by us.
We guarantee the performance of our products only when they are assembled and adjusted as described in this
manual.
The specifications and external designs shown in this manual are subject to change without notice.
CAUTION
Exclamation marks placed within triangles are intended to alert users to the presence of important safety
information. Be sure to read instructions indicated by this symbol.
This manual provides precautions and information for installation, preparation, and handling of the handwriting device.
Before installation and preparatory work, choose a safe and appropriate site after thorough consideration of
construction, materials used, strength, and surroundings. If adequate safeguards are not in place, immediately halt the
installation process and discontinue marketing activities.
TECHNICAL MANUAL
(Ver. 1.0)