Reebok Rb 345 Bike English Manual - Page 20

Maintenance And Troubleshooting

Page 20 highlights

MAINTENANCE AND TROUBLESHOOTING Inspect and properly tighten all parts of the exercise cycle regularly. The exercise cycle can be cleaned with a soft, damp cloth. To prevent damage to the console, keep liquids away from the console and keep the console out of direct sunlight. TIGHTENING THE PEDALS For best performance, regularly tighten both pedals. CONSOLE TROUBLESHOOTING If the console display becomes dim, the batteries should be replaced. See assembly step 4 on page 5 for replacement instructions. If the console does not display your heart rate when you use the handgrip pulse sensor, see step 5 on page 13. HOW TO LEVEL THE EXERCISE CYCLE If the exercise cycle does not sit flat on the floor, turn one or both of the leveling pads until the exercise cycle is level. Leveling Pads HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, remove the indicated M4 x 48mm Screws (20) and M4 x 16mm Screws (21) from the Left Side Shield (4). Using an adjustable wrench, turn the Left Pedal (40) clockwise and remove it. Turn the left side of the Crank (19) so that it is pointing toward the front of the exercise cycle, and then slide off the Left Side Shield. Locate the Reed Switch (44). Turn the Crank (19) until the Magnet (54) is 54 21 aligned with the Reed Switch. 44 Loosen, but do not remove, the 19 indicated M4 x 16mm Screw (21). Slide the Reed Switch slightly closer to or away from the Magnet. Then, retighten the Screw. Turn the Left Crank Arm for a moment. Repeat until the console displays correct feedback. When the Reed Switch is correctly adjusted, reattach the left side shield and the left pedal. HOW TO ADJUST THE DRIVE BELT If you can feel the pedals slip while you are pedaling, even when the resistance is at the highest level, the Drive Belt (64) may need to be adjusted. See HOW TO ADJUST THE REED SWITCH at the left. To adjust the Drive Belt, the Right Side Shield (5) must first be removed. Remove the indicated M4 x 48mm Screws (20) from the Left Side Shield (4) and the M4 x 16mm Screws (not shown) from the Right Side Shield. Using an adjustable wrench, turn the Right Pedal (not shown) counterclockwise and remove it. Next, turn the right side of the Crank (19) so that it is pointing toward the front of the exercise cycle, and then slide off the Right Side Shield. 19 20 40 21 4 5 Next, turn the indicated M8 x 35mm Screw (72) until the Drive Belt (64) is properly tightened. Then, reattach the right side shield and the right pedal. 64 72 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

20
Inspect and properly tighten all parts of the exercise
cycle regularly. The exercise cycle can be cleaned
with a soft, damp cloth. To prevent damage to the
console, keep liquids away from the console and keep
the console out of direct sunlight.
TIGHTENING THE PEDALS
For best performance, regularly tighten both pedals.
CONSOLE TROUBLESHOOTING
If the console display becomes dim, the batteries
should be replaced. See assembly step 4 on page 5
for replacement instructions. If the console does not
display your heart rate when you use the handgrip
pulse sensor, see step 5 on page 13.
HOW TO LEVEL THE EXERCISE CYCLE
If the exercise
cycle does not sit
flat on the floor,
turn one or both
of the leveling
pads until the
exercise cycle is
level.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, remove the indicated M4 x 48mm Screws (20)
and M4 x 16mm Screws (21) from the Left Side
Shield (4). Using an adjustable wrench, turn the Left
Pedal (40) clockwise and remove it. Turn the left side
of the Crank (19) so that it is pointing toward the front
of the exercise cycle, and then slide off the Left Side
Shield.
Locate the
Reed Switch
(44). Turn the
Crank (19)
until the
Magnet (54) is
aligned with
the Reed
Switch.
Loosen, but
do not
remove, the
indicated M4
x 16mm Screw (21). Slide the Reed Switch slightly
closer to or away from the Magnet. Then, retighten
the Screw. Turn the Left Crank Arm for a moment.
Repeat until the console displays correct feedback.
When the Reed Switch is correctly adjusted, reattach
the left side shield and the left pedal.
HOW TO ADJUST THE DRIVE BELT
If you can feel the pedals slip while you are pedaling,
even when the resistance is at the highest level, the
Drive Belt (64) may need to be adjusted. See HOW
TO ADJUST THE REED SWITCH at the left. To adjust
the Drive Belt, the Right Side Shield (5) must first be
removed. Remove the indicated M4 x 48mm Screws
(20) from the Left Side Shield (4) and the M4 x 16mm
Screws (not shown) from the Right Side Shield. Using
an adjustable wrench, turn the Right Pedal (not
shown) counterclockwise and remove it. Next, turn the
right side of the Crank (19) so that it is pointing
toward the front of the exercise cycle, and then slide
off the Right Side Shield.
Next, turn the
indicated M8 x
35mm Screw
(72) until the
Drive Belt (64)
is properly
tightened.
Then, reattach
the right side
shield and the
right pedal.
M
AINTENANCE AND
T
ROUBLESHOOTING
Leveling
Pads
20
21
5
4
40
72
19
64
44
21
54
19