Reebok Rx4000 English Manual - Page 26
Plug The Power Cord.
View all Reebok Rx4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
PROBLEM 4. The walking belt is off-center or slips when walked on SOLUTION a. If the walking belt is off-center, first re- a move the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the allen wrench to turn the left rear roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered b. If the walking belt slips when walked on, b first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller bolts clockwise 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key, and walk on the tread- mill for a few minutes. Repeat until the walking belt is properly tightened. 5. The displays of the console do not function properly a. Remove the key from the console and UN- a PLUG THE POWER CORD. Next, remove 1/8" the screws from the hood and carefully re- move the hood. Locate the Reed Switch 99 11 (17) and the Magnet (12) on the left side of 17 12 the Pulley (11). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Top View Magnet and the Reed Switch is about 1/8". If necessary, loosen the Reed Switch Screw (99) and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood and run the treadmill for a few minutes to check for a correct speed reading. 6. The heart rate monitor a. If the heart rate monitor does not function properly, does not function refer to CHEST PULSE SENSOR TROUBLE-SHOOT- b properly ING on page 7. b. If the heart rate monitor still does not function properly, the battery should be changed. To replace the battery, locate the battery cover on the back of the sensor unit. Insert a coin into the slot in the cover and turn the cover counterclockwise to the "open" position. Remove the cover. Next, remove the old battery from the sensor unit. Insert a new CR 2032 battery, making sure that the writing is on top. In addition, make sure that the rubber gasket is in place in the sensor unit. Replace the battery cover and turn it to the closed position. CR2032 Battery Rubber Gasket 26