Rheem Fury Electric Series Specifications - Page 2

Fury Water Heaters

Page 2 highlights

Residential Electric WI NaTtEeGrR AT ED HOM Fury E COMFO Water RT Heaters T Y P E T A L L MED. S H O R T DESCRIPTION GAL. CAP. MODEL NUMBER 30 82V30-2 40 83VR40-2† 40 82V40-2 40 82VH40-2 50 83VR52-2† 50 82V52-2 65 83VR66-2† 65 82V66-2 80 83VR80-2† 80 82V80-2 120 82V120-2 30 82MV30-2 50 83MVR52-2† 50 82MV52-2 20 82SV20-2 30 81SVB30-2* 30 82SV30-2 38 82SV40-2 38 82SVB40-2* 47 82SV50-2 FEATURES FIRST HOUR RATING G.P.H. RECOVERY IN G.P.H. @ 90° RISE 48 21 56 21 53 21 57 21 67 21 67 21 71 21 71 21 88 21 88 21 99 21 44 21 62 21 62 21 - 21 42 21 42 21 45 21 45 21 55 21 ROUGHING IN DIMENSIONS (SHOWN IN INCHES) TANK HEIGHT A HEIGHT TO WATER CONN. B DIAMETER C APPROX. SHIP WT. (LBS.) 45-3/4 45-3/4 17-3/4 80 46-3/4 46-3/4 22-1/4 104 46-1/2 46-1/2 19-3/4 95 59-1/4 59-1/4 17-3/4 96 57 57 22-1/4 123 57 57 19 107 58-3/4 58-3/4 23 160 58-1/2 58-1/2 21 150 59 59 24-1/2 181 59 59 23 177 62-1/2 62-1/2 28-1/4 324 36 36 19-3/4 80 46 46 24-1/4 128 46 46 21-3/4 117 31-1/2 31-1/2 17 62 30 30 19-3/4 90 30 30 22-1/4 83 31-1/2 31-1/2 23 108 31-1/2 31-1/2 23 108 32 32 26-1/4 149 ENERGY INFO. ENERGY FACTOR AVERAGE ANNUAL OPER. COST 0.93 $503 0.95 $492 0.92 $508 0.92 $508 0.95 $492 0.91 $514 0.92 $508 0.89 $525 0.92 $508 0.86 $544 0.85 $550 0.93 $503 0.93 $503 0.90 $520 N/A N/A 0.93 $503 0.93 $503 0.92 $508 0.93 $503 0.91 $514 *Water heater dimensions prior to installing insulation blanket that is included with water heater. 81SVB30-2 - The insulation blanket adds 1-1/2 inches to tank height and 3 inches to tank diameter. 82SVB40-2 - The insulation blanket adds 1 inch to tank height and 2 inches to tank diameter. • Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating elements. • If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested. • Single element models available on special order (6000W max.). Substitute "-1" for "-2" in model number. • Special Wiring Options - A limited number of special wiring options are available. Consult factory for price and availability. • All models equipped with heat traps. **Recovery = wattage/2.42 x temp. rise °F. Example: 4500W = 21 GPH 2.42 x 90° 8" HOT WATER CONNECTION RELIEF VALVE CONNECTION C DIAMETER COLD WATER CONNECTION ANODE ROD **Recovery calculations used are based on 4500 watt elements used in non-simultaneous operation. Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate A electricity 10.65¢/KWH. B †LEED Point = 1 WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • www.rheem.com IINNTTEEGGRRAATETDE DHOHMOEMCEOCMOFOMRFTO RT 2 PRINTED IN U.S.A. 05/12 WP FORM NO. 101-5 Rev. 36

  • 1
  • 2

PRINTED IN U.S.A. 05/12 WP FORM NO. 101-5 Rev. 36
2
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating
101 Bell Road
Montgomery, Alabama 36117-4305
www.rheem.com
Rheem Canada Ltd./Ltée
125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5
www.rheem.com
INTEGRATED HOME COMFORT
Water
Residential Electric
Fury Water Heaters
DESCRIPTION
FEATURES
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
ENERGY INFO.
RECOVERY
TANK
HEIGHT TO
APPROX.
AVERAGE
GAL.
FIRST HOUR
IN G.P.H.
HEIGHT
WATER CONN.
DIAMETER
SHIP WT.
ENERGY
ANNUAL
CAP.
MODEL NUMBER
RATING G.P.H.
@ 90° RISE
A
B
C
(LBS.)
FACTOR
OPER. COST
30
82V30-2
48
21
45-3/4
45-3/4
17-3/4
80
0.93
$503
40
83VR40-2
56
21
46-3/4
46-3/4
22-1/4
104
0.95
$492
40
82V40-2
53
21
46-1/2
46-1/2
19-3/4
95
0.92
$508
40
82VH40-2
57
21
59-1/4
59-1/4
17-3/4
96
0.92
$508
50
83VR52-2
67
21
57
57
22-1/4
123
0.95
$492
50
82V52-2
67
21
57
57
19
107
0.91
$514
65
83VR66-2
71
21
58-3/4
58-3/4
23
160
0.92
$508
65
82V66-2
71
21
58-1/2
58-1/2
21
150
0.89
$525
80
83VR80-2
88
21
59
59
24-1/2
181
0.92
$508
80
82V80-2
88
21
59
59
23
177
0.86
$544
120
82V120-2
99
21
62-1/2
62-1/2
28-1/4
324
0.85
$550
30
82MV30-2
44
21
36
36
19-3/4
80
0.93
$503
50
83MVR52-2
62
21
46
46
24-1/4
128
0.93
$503
50
82MV52-2
62
21
46
46
21-3/4
117
0.90
$520
20
82SV20-2
21
31-1/2
31-1/2
17
62
N/A
N/A
30
81SVB30-2*
42
21
30
30
19-3/4
90
0.93
$503
30
82SV30-2
42
21
30
30
22-1/4
83
0.93
$503
38
82SV40-2
45
21
31-1/2
31-1/2
23
108
0.92
$508
38
82SVB40-2*
45
21
31-1/2
31-1/2
23
108
0.93
$503
47
82SV50-2
55
21
32
32
26-1/4
149
0.91
$514
T
Y
P
E
T
A
L
L
MED.
S
H
O
R
T
*Water heater dimensions prior to installing insulation blanket that is included with water heater.
81SVB30-2 - The insulation blanket adds 1-1/2 inches to tank height and 3 inches to tank diameter.
82SVB40-2 - The insulation blanket adds 1 inch to tank height and 2 inches to tank diameter.
• Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating elements.
• If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested.
• Single element models available on special order (6000W max.). Substitute “-1” for “-2” in model number.
• Special Wiring Options – A limited number of special wiring options are available. Consult factory for price and availability.
• All models equipped with heat traps.
**Recovery calculations used are based on 4500 watt elements used in non-simultaneous operation.
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate
electricity 10.65¢/KWH.
LEED Point = 1
**Recovery = wattage/2.42 x temp. rise °F.
Example:
4500W
= 21 GPH
2.42 x 90°
C
DIAMETER
A
B
HOT
WATER
CONNECTION
COLD
WATER
CONNECTION
ANODE
ROD
RELIEF VALVE
CONNECTION
8"