Rheem RANL-JEZ Brochure

Rheem RANL-JEZ Manual

Rheem RANL-JEZ manual content summary:

  • Rheem RANL-JEZ | Brochure - Page 1
    's atmosphere. The Rheem Prestige® Series RAPL- JEZ and RANL- JEZ Condensing Units are the compressors by detecting system and electrical problems without adding sensors. It can condenser coil. I Single speed 8-pole fan motor designed for low speed, quiet, energy-saving operation. I All models meet or
  • Rheem RANL-JEZ | Brochure - Page 2
    also has low start torque, eliminating start problems in the field. And its unique design enables the RAPL- JEZ and RANL- JEZ condensing units to perform efficiently, quietly and dependably. All controls and compressor are accessible for servicing by removal of the service panel. 2 Rheem
  • Rheem RANL-JEZ | Brochure - Page 3
    Model Number Identification R A RHEEM REMOTE CONDENSING UNIT P P = 14 SEER N = 13 SEER L DESIGN SERIES L = R-410A A* - VAR0I1AT8IONS A =COSTOALNINDGARD CAPACITY FITTING Z = SWEAT W/SCROLL Field Installed Accessories I Low Ambient Control-Cycles outdoor fan to maintain adequate condensing
  • Rheem RANL-JEZ | Brochure - Page 4
    Performance Data @ ARI Standard Conditions-Cooling: RAPL- JEZ Outdoor Unit RAPL- 018JEZ 024JEZ Model Numbers Indoor Coil and/or Air [378] 800 [378] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 4 Rheem Manufacturing Company
  • Rheem RANL-JEZ | Brochure - Page 5
    Performance Data @ ARI Standard Conditions-Cooling: RAPL- JEZ (continued) Outdoor Unit RAPL- 024JEZ 030JEZ Model Numbers Indoor Coil and/ [448] 950 [448] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions Rheem Manufacturing Company 5
  • Rheem RANL-JEZ | Brochure - Page 6
    Performance Data @ ARI Standard Conditions-Cooling: RAPL- JEZ (continued) Outdoor Unit RAPL- 030JEZ 036JEZ Model Numbers Indoor Coil [566] 1,200 [566] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 6 Rheem Manufacturing Company
  • Rheem RANL-JEZ | Brochure - Page 7
    Performance Data @ ARI Standard Conditions-Cooling: RAPL- JEZ (continued) Outdoor Unit RAPL- 036JEZ 042JEZ Model Numbers Indoor Coil [661] 1,450 [684] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions Rheem Manufacturing Company 7
  • Rheem RANL-JEZ | Brochure - Page 8
    Performance Data @ ARI Standard Conditions-Cooling: RAPL- JEZ (continued) Outdoor Unit RAPL- 042JEZ 048JEZ Model Numbers Indoor Coil [743] 1,600 [755] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 8 Rheem Manufacturing Company
  • Rheem RANL-JEZ | Brochure - Page 9
    Performance Data @ ARI Standard Conditions-Cooling: RAPL- JEZ (continued) Outdoor Unit RAPL- 048JEZ 060JEZ Model Numbers Indoor Coil [849] 1,800 [849] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions Rheem Manufacturing Company 9
  • Rheem RANL-JEZ | Brochure - Page 10
    Performance Data @ ARI Standard Conditions-Cooling: RANL- JEZ Outdoor Unit RANL- Model Numbers Indoor Coil and/or Air Handler 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor 1,000 [472] 14.00 73 1,000 [472] 14.00 73 1,000 [472] [ ] Designates Metric Conversions 10 Rheem Manufacturing Company
  • Rheem RANL-JEZ | Brochure - Page 11
    Performance Data @ ARI Standard Conditions-Cooling: RANL- JEZ (continued) Outdoor Unit RANL- 030JEZ 036JEZ Model Numbers Indoor Coil and/or Air [578] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions Rheem Manufacturing Company 11
  • Rheem RANL-JEZ | Brochure - Page 12
    Performance Data @ ARI Standard Conditions-Cooling: RANL- JEZ (continued) Outdoor Unit RANL- 036JEZ 042JEZ Model Numbers Indoor Coil and/or Air [672] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 12 Rheem Manufacturing Company
  • Rheem RANL-JEZ | Brochure - Page 13
    Performance Data @ ARI Standard Conditions-Cooling: RANL- JEZ (continued) Outdoor Unit RANL- 042JEZ 048JEZ Model Numbers Indoor Coil and/or Air [672] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions Rheem Manufacturing Company 13
  • Rheem RANL-JEZ | Brochure - Page 14
    Performance Data @ ARI Standard Conditions-Cooling: RANL- JEZ (continued) Outdoor Unit RANL- 048JEZ 048JEZ Model Numbers Indoor Coil and/or Air 767] ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions 14 Rheem Manufacturing Company
  • Rheem RANL-JEZ | Brochure - Page 15
    Performance Data @ ARI Standard Conditions-Cooling: RANL- JEZ (continued) Outdoor Unit RANL- Model Numbers Indoor Coil and/or Air Handler 80°F [26.5°C] DB/67°F [19.5°C] 1,800 [849] 13.50 76 1,800 [849] 13.50 76 1,800 [849] [ ] Designates Metric Conversions Rheem Manufacturing Company 15
  • Rheem RANL-JEZ | Brochure - Page 16
    RANL- JEZ Model No. RANL LOW VOLTAGE 7/8Љ [22 mm] ACCESS PANEL ALLOW 24Љ [610 mm] ACCESS CLEARANCE HIGH VOLTAGE 111/32Љ [34 mm] VAPOR LINE A-00003 CONNECTION HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY) LIQUID LINE CONNECTION 27/8Љ [73 mm] DIA. ACCESSORY KNOCKOUTS SERVICE
  • Rheem RANL-JEZ | Brochure - Page 17
    N/A N/A N/A N/A NOTES: *Standard line size Using suction line larger than shown in chart will result in poor oil return and is not recommended. [ ] Designates Metric Conversions Rheem Manufacturing Company 17
  • Rheem RANL-JEZ | Brochure - Page 18
    NOTES 18 Rheem Manufacturing Company
  • Rheem RANL-JEZ | Brochure - Page 19
    NOTES Rheem Manufacturing Company 19
  • Rheem RANL-JEZ | Brochure - Page 20
    2001. RAPL- JEZ/RANL- JEZ Conditional Replacement Warranty: Rheem will provide a instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

The Rheem
Prestige
®
Series
High Efficiency RAPL- JEZ and
RANL- JEZ Condensing Units were designed with performance in
mind. These units offer comfort, energy conservation and depend-
ability for single, multi-family and light commercial applications.
These units also contain the most advanced alternate refrigerant
which contains no chlorofluorocarbons (CFCs), or hydrochloroflu-
orocarbons (HCFCs), or other compounds that may leak from air-
conditioning systems and potentially harm the protective ozone
layer of the Earth’s atmosphere.
The Rheem
Prestige
®
Series
RAPL- JEZ and RANL- JEZ Con-
densing Units are the result of an ongoing development program
for improved efficiencies. These units are flexible enough to
achieve up to 15.50 SEER in specific match-ups, continuing a
tradition of high efficiency.
The
Comfort Control System
provides on-board diagnostics
and fault history for condensing units with single-phase com-
pressors by detecting system and electrical problems without
adding sensors. It can also communicate “fault codes” to
enabled “L terminal” thermostats. The integrated diagnostics
with
Active Protection
prevents compressor operation when
potentially harmful conditions are detected.
7-Segment LED Display is exclusive only to Rheem products. The
information-display quickly and accurately shows technicians the
source of malfunctions.
Five-year conditional unit replacement warranty.
Compressor sound blanket is standard to provide quiet operation.
Attractive, louvered wrap-around jacket protects the coil from
yard hazards and weather extremes. Top grille is steel rein-
forced for extra strength. Cabinet is powder painted for all-
weather protection.
Air is discharged upward away from bushes and shrubs. The dis-
charge pattern of the top grille provides minimum air restriction.
Combination Grille/Motor Mount secures the motor to the
underside of the discharge grille. The grille protects the motor
windings and bearings from rain and snow.
Removable top grille provides access to the condenser fan
motor and condenser coil.
Single speed 8-pole fan motor designed for low speed, quiet,
energy-saving operation.
All models meet or exceed a 1000-hour salt spray test per
ASTM B117 Standard Practice for Operating Salt Spray Testing
Apparatus.
CONDENSING UNITS
FORM NO. A11-187 REV. 2
Supersedes Form No. A11-187 Rev. 1
13.0
Equipped with
Comfort Control System
• Increased Reliability
• On-Board Diagnostics
• Fault Recall
Active Protection
14 SEER MODELS &
13 SEER MODELS
(IN CERTAIN MATCHED SYSTEMS)
ear th friendly refrigerant
RANL- JEZ
13 SEER Models
Nominal Sizes 2 to 5 Tons
[7.03 kW] to [17.6 kW]
Six Models
Cooling Capacities
23,200 to 62,000 BTU/HR
[6.80 kW] to [18.17 kW]
ear th friendly refrigerant
RAPL- JEZ
14 SEER Models
Efficiencies up to 15.50 SEER
Nominal Sizes 1
1
/
2
to 5 Tons
[5.28 kW] to [17.6 kW]
Seven Models
Cooling Capacities
18,200 to 59,500 BTU/HR
[5.33 kW] to [17.44 kW]