Rheem RANL-JEZ Brochure - Page 3

Field Installed Accessories, Model Number Identification - inc

Page 3 highlights

Model Number Identification R A RHEEM REMOTE CONDENSING UNIT P P = 14 SEER N = 13 SEER L DESIGN SERIES L = R-410A A* - VAR0I1AT8IONS A =COSTOALNINDGARD CAPACITY 018 = 18,000 BTU/HR [5.28 kW] (RAPL MODELS ONLY) 024 = 24,000 BTU/HR [7.03 kW] 030 = 30,000 BTU/HR [8.79 kW] 036 = 36,000 BTU/HR [10.55 kW] 042 = 42,000 BTU/HR [12.31 kW] 048 = 48,000 BTU/HR [14.07 kW] 060 = 60,000 BTU/HR [17.58 kW] J ELECTRICAL DESIGNATION J = 208/230V-1-60 E VARIATIONS EQUIPPED WITH THE COMFORT CONTROL SYSTEM™ Z COOLING CONNECTION FITTING Z = SWEAT W/SCROLL Field Installed Accessories I Low Ambient Control-Cycles outdoor fan to maintain adequate condensing pressures assuring liquid refrigerant flow to the coil. Allows indoor cooling with outdoor temperatures down to 0°F [-17.8°C]. (Model No. RXAD-A04) It is recommended that this control be installed in units to be operated at outdoor ambient temperatures under 45°F [7°C]. I Thermostats- I Compressor Crankcase Heater (CCH)-While scroll compressors usually do not require crankcase heaters, there are instances when a heater should be added. Refrigerant migration during the off cycle can result in a noisy start up. Add a crankcase heater to minimize refrigeration migration, and to hep eliminate any start up noise or bearing "wash out." [ ] Designates Metric Conversions Rheem Manufacturing Company 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Rheem Manufacturing Company
3
A*
VARIATIONS
A = STANDARD
R
A
P
L
018
J
E
Z
RHEEM
REMOTE
CONDENSING
UNIT
P = 14 SEER
N = 13 SEER
DESIGN
SERIES
L = R-410A
ELECTRICAL
DESIGNATION
J = 208/230V-1-60
VARIATIONS
EQUIPPED WITH
THE
COMFORT
CONTROL SYSTEM
COOLING
CONNECTION
FITTING
Z = SWEAT
W/SCROLL
COOLING
CAPACITY
018 = 18,000 BTU/HR
[5.28 kW]
(RAPL MODELS ONLY)
024 = 24,000 BTU/HR
[7.03 kW]
030 = 30,000 BTU/HR
[8.79 kW]
036 = 36,000 BTU/HR [10.55 kW]
042 = 42,000 BTU/HR [12.31 kW]
048 = 48,000 BTU/HR [14.07 kW]
060 = 60,000 BTU/HR [17.58 kW]
Field Installed Accessories
Low Ambient Control
—Cycles outdoor fan to maintain
adequate condensing pressures assuring liquid refrigerant
flow to the coil. Allows indoor cooling with outdoor
temperatures down to 0°F [–17.8°C]. (Model No. RXAD-A04)
It is recommended that this control be installed in units
to be operated at outdoor ambient temperatures under
45°F [7°C].
Thermostats
Compressor Crankcase Heater (CCH)
—While scroll
compressors usually do not require crankcase heaters, there
are instances when a heater should be added. Refrigerant
migration during the off cycle can result in a noisy start up.
Add a crankcase heater to minimize refrigeration migration,
and to hep eliminate any start up noise or bearing “wash out.”
Model Number Identification
[
] Designates Metric Conversions