Samsung CLP 300N Service Manual - Page 58
LSU(Laser Scan Unit), 5.4.4 HVPS(High Voltage Power Supply)
UPC - 635753722093
View all Samsung CLP 300N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
Disassembly and Reassembly 5.4.3 LSU(Laser Scan Unit) 1. Follow step 1 through step 3 in Cover Unit Disassembly 2. Lift up the LSU Cover(as shown in Picture) and then take out. 3. Remove 4 screws and then take out the LSU. 5.4.4 HVPS(High Voltage Power Supply) 1. Follow step 1 through step 5 in Cover Unit Disassembly except removing Righ Cover 2. Unscrew 6 screws and then take out the HVPS. Be careful of taking out the HVPS because there are 7 High Voltage Terminal behind HVPS. 5-12 Service Manual Samsung Electronics
Samsung Electronics
Service Manual
Disassembly and Reassembly
5-12
1. Follow step 1 through step 3 in Cover Unit
Disassembly
2. Lift up the LSU Cover(as shown in Picture) and then
take out.
3. Remove 4 screws and then take out the LSU.
5.4.3 LSU(Laser Scan Unit)
1. Follow step 1 through step 5 in Cover Unit
Disassembly except removing Righ Cover
2. Unscrew 6 screws and then take out the HVPS.
Be careful of taking out the HVPS because there are
7 High Voltage Terminal behind HVPS.
5.4.4 HVPS(High Voltage Power Supply)