Samsung DV42H5200GW/A3 Trouble Shooting Guide Tech Manual (English, French, Sp - Page 8
Gas Model, Warning, Thermistor
View all Samsung DV42H5200GW/A3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. THERMISTOR 238.23Ω @ 25 °C 77 GAS MODEL Radiant Sensor(10RS) Resistance value < 1 Ω If resistance is infinite, replace Radiant sensor Gas Valve(25M01A) Valve 1-2 : Resistance value about 1365 Ω Valve 1-3 : Resistance value about 560 Ω Valve 4-5 : Resistance value about 1325 Ω If resistance is infinity, replace Valve Igniter(101D) Resistance value 40~400 Ω If resistance is infinite, replace Igniter Thermostat (60T21 Hi-Limit)230F-50F Resistance value < 1 Ω If resistance is infinity, replace Thermostat 8 Technical_information-03382A_EN_131209.indd 8 2013-12-09 �� 5:37:35
8
GAS MODEL
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is infinite, replace Radiant sensor
Igniter(101D)
Resistance value 40~400 Ω
If resistance is infinite, replace Igniter
Gas Valve(25M01A)
Valve 1-2 : Resistance value about 1365 Ω
Valve 1-3 : Resistance value about 560 Ω
Valve 4-5 : Resistance value about 1325 Ω
If resistance is infinity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is infinity, replace Thermostat
THERMISTOR
238.23Ω @ 25 °C 77
Technical_information-03382A_EN_131209.indd
8
2013-12-09
�� 5:37:35