Samsung DV484ETHAWR/A1 Trouble Shooting Guide User Manual Ver.1.0 (English, Fr - Page 4
Data Display Mode, System Check Mode, WARNING
View all Samsung DV484ETHAWR/A1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Data Display Mode Definition of Data Display Mode: - Display Mode 1 : Temperature data(Celsius) - Display Mode 2 : Average Touch Sensor data for 1 minute - Display Mode 3 : Average Temperature(Celsius) data for 1minute How to Enter: - With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a beeping sound . - If not pressed any keys for 5 minutes, it will be set back from Data Display Mode - If pressing AdjustUp Key in this mode, Display Mode will be increased. - If pressing AdjustDown Key in this mode, Display Mode will be decreased. • Converting °C °F Celsius(°C) Fahrenheit(°F) -30 -10 10 30 50 70 F =9/5C + 32 -22 14 50 86 122 158 System Check Mode Definition of System Check Mode: - " t2 " will display. - System Check Mode(t2 mode) Progress Function Performed Start/Pause Motor(CW) Relay On Heater Relay On Heater Relay Off, Motor(CW) Relay Off How to Enter: - While in Power Off, pressing the Dry Level + Power keys simultaneously will put the dryer into the System Check mode 4 Technical_information-03044B_EN.indd 4 2012-05-30 �� 9:56:26