Samsung DV50K7500GW/A3 User Manual - Page 25
Using the short hose as an extension, short hose B, Y connector A, water, hoses C
View all Samsung DV50K7500GW/A3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Installation Using the short hose as an extension B A C 1. Close the cold water tap. If you have a washer cold water hose attached to the cold water faucet, unscrew and remove the hose. Then, connect the short hose (B) to the cold water tap. Turn the coupling by hand until it is tight. 2. Using pliers, tighten the coupling an additional two-thirds turn. Do not overtighten. You can damage the coupling. 3. Connect the Y connector (A) to the brass male end of the short hose. Turn the coupling by hand until it is tight. 4. Using pliers, tighten the coupling an additional two-thirds turn. Do not overtighten. You can damage the coupling. 5. Connect the angled end of the water hoses (C) to the filling valve at the bottom rear of the dryer. Turn the coupling by hand until it is tight. 6. Using pliers, tighten the coupling an additional two-thirds turn. Do not overtighten. You can damage the coupling. 7. If you detached the cold water hose from your washer, attach the hose to the free end of the Y connector, tighten the coupling by hand until it is tight, and then, using a pliers, tighten an additional two-thirds turn. 8. Open the cold water tap, and then check for any leaks. DV7500K-03381C-02_EN.indd 25 English 25 4/7/2016 5:05:46 PM