Alcove Or Closet Installation
View all Samsung DV511AGW/XAA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
01 installing your dryer ALCOVE OR CLOSET INSTALLATION The dryer must be exhausted to the outside to reduce the risk of fire when installed in an alcove or WARNING closet. • No other fuel-burning appliance should be installed in the same closet as the dryer. • WARNING: To reduce the risk of fire, this dryer must be exhausted to the outdoors. See Exhaust information section. MINIMUM CLEARANCES FOR CLOSET AND ALCOVE INSTALLATIONS: Sides - 1 in / 25 mm Top - 17 in / 432 mm Rear - 4 in / 102 mm Closet Front - 2 in / 51 mm If the washer and dryer are installed together, the closet front must have at least a 72 in² (465 cm²) unobstructed air opening. A 1 in. (2.5 cm) B 17 in. (43.2 cm) 1 in. (2.5 cm) 27 in. (68.6 cm) 27 in. (68.6 cm) A. Recessed area B. Side view - closet or confined area 1 in. (2.5 cm) 2 in. (5 cm) 34.1 in. (86.5 cm) 4 in. (10.2 cm) DV511AE-02836C_EN.indd Sec2:13 installing your dryer _13 2010-12-15 11:45:36