Samsung LH40MGQLBF/ZA User Manual (ENGLISH) - Page 91

PowerSaver, PowerSaver (When used as a Network monitor)

Page 91 highlights

Specifications Plug and Play Capability This LCD Display can be installed on any Plug & Play compatible system. The interaction of the LCD Display and the computer systems will provide the best operating conditions and LCD Display settings. In most cases, the LCD Display installation will proceed automatically, unless the user wishes to select alternate settings. Dot Acceptable TFT-LCD panels manufactured by using advanced semiconductor technology with precision of 1ppm (one millionth) above are used for this product. But the pixels of RED, GREEN, BLUE and WHITE color appear to be bright sometimes or some black pixels may be seen. This is not from bad quality and you can use it without any problems. For example, the number of TFT-LCD sub pixels contained in this product are 6,220,800. Note Design and specifications are subject to change without prior notice. Class B Equipment (Information Communication equipment for residential use) This product complies with the Electromagnetic Compatibility Directives for residential use and can be used in all areas including common residential areas. (Class B equipment emits less electromagnetic waves than Class A equipment.) PowerSaver This LCD Display has a built-in power management system called PowerSaver. This system saves energy by switching your LCD Display to low-power mode when it has not been used for a certain amount of time. The LCD Display automatically returns to normal operation when you press a key on the keyboard. For energy conservation, turn your LCD Display OFF when it is not needed, or when leaving it unattended for long periods. The PowerSaver system operates with a VESA DPM compliant video card installed in your computer. Use the software utility installed on your computer to set up this feature. PowerSaver (When used as a Network monitor) State Normal Operation Power Indicator Power 400FPnConsump- 2 tion 460FPn2 On 228 W 310 W Power saving mode Blinking Less than 5 W Less than5 W Power off (Power-switch) Off 0 W 0 W PowerSaver (When used as a normal monitor) State Normal Operation Power Indicator Power 400FP-2 Consump- 460FP-2 tion On 180 W 240 W Power saving mode Blinking Less than 2 W Less than2 W Power off (Power-switch) Off 0 W 0 W

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

Plug and Play Capability
This LCD Display can be installed on any Plug & Play compatible system. The
interaction of the LCD Display and the computer systems will provide the best op-
erating conditions and LCD Display settings. In most cases, the LCD Display
installation will proceed automatically, unless the user wishes to select alternate
settings.
Dot Acceptable
TFT-LCD panels manufactured by using advanced semiconductor technology with
precision of 1ppm (one millionth) above are used for this product. But the pixels of
RED, GREEN, BLUE and WHITE color appear to be bright sometimes or some
black pixels may be seen. This is not from bad quality and you can use it without
any problems.
For example, the number of TFT-LCD sub pixels contained in this product are
6,220,800.
Note
Design and specifications are subject to change without prior notice.
Class B Equipment (Information Communication equipment for residential use)
This product complies with the Electromagnetic Compatibility Directives for residential use
and can be used in all areas including common residential areas. (Class B equipment emits
less electromagnetic waves than Class A equipment.)
PowerSaver
This LCD Display has a built-in power management system called PowerSaver. This system
saves energy by switching your LCD Display to low-power mode when it has not been used
for a certain amount of time. The LCD Display automatically returns to normal operation when
you press a key on the keyboard. For energy conservation, turn your LCD Display OFF when
it is not needed, or when leaving it unattended for long periods. The PowerSaver system
operates with a VESA DPM compliant video card installed in your computer. Use the software
utility installed on your computer to set up this feature.
PowerSaver (When used as a Network monitor)
State
Normal Operation
Power saving
mode
Power off
(Power-switch)
Power Indicator
On
Blinking
Off
Power
Consump-
tion
400FPn-
2
228 W
Less than 5 W
0 W
460FPn-
2
310 W
Less than5 W
0 W
PowerSaver (When used as a normal monitor)
State
Normal Operation
Power saving
mode
Power off
(Power-switch)
Power Indicator
On
Blinking
Off
Power
Consump-
tion
400FP-2
180 W
Less than 2 W
0 W
460FP-2
240 W
Less than2 W
0 W
Specifications