Samsung SDP-950STA Reference Guide - Page 3
RS232C Command Code
View all Samsung SDP-950STA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
RS232C Command Code Command AWC AF Upper Lamp Lower Lamp Lamp OFF Internal External 1 External 2 Positive Negative NTSC PAL Aperture ON Aperture OFF Power ON Power OFF Rotate OFF Rotate 90° Rotate 180° Rotate 360° PC Transmit Data to MICOM 1st 0 x 01 0 x 02 0 x 03 0 x 04 0 x 05 0 x 08 0 x 09 0 x 0F 0 x 11 2nd 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 3rd 0 x 05 0 x 05 0 x 05 0 x 08 0 x 0A 0 x 05 0 x 08 0 x 0A 0 x 05 0 x 0A 0 x 05 0 x 0A 0 x 05 0 x 0A 0 x 05 0 x 0A 0 x 05 0 x 08 0 x 0A 0 x 0D 4th 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 PC Receive Data from MICOM 1st 0 x 01 0 x 02 0 x 03 0 x 04 0 x 05 0 x 08 0 x 09 0 x 0F 0 x 11 2nd "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" "ACK data" 3rd 0 x 05 0 x 05 0 x 05 0 x 08 0 x 0A 0 x 05 0 x 08 0 x 05 0 x 0A 0 x 05 0 x 0A 0 x 05 0 x 0A 0 x 05 0 x 0A 0 x 05 0 x 08 0 x 0A 0 x 0D 4th 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 0 x 00 Remark 3