RS232C Command Code (UF-130DX/ST) Command PC Transmit Data to MICOM 1st 2nd 3rd 4th PC Receive Data from MICOM 1st 2nd 3rd 4th Remark Focus Far Focus Near 0x25 0x00 0x00 0x05 0x0A 0x00 0x00 0x25 "ACK data" "ACK data" 0x05 0x0A 0x00 0x00 Zoom Tele Zoom Wide 0x26 0x00 0x00 0x05 0x0A 0x00 0x00 0x26 "ACK data" "ACK data" 0x05 0x0A 0x00 0x00 Range : "1~120" Iris Target Red Target Blue Target 0x41 0x43 0x44 0x00 0x00 0x00 0x00 0x00 0x00 "data" "data" "data" 0x41 0x43 0x44 "ACK data" "ACK data" "ACK data" 0x00 0x00 0x00 "data" "data" "data" Range : "1~120" Range : "1~200" Range : "1~200" Focus Target 0x45 0x00 "MSBdata" "LSBdata" 0x45 "ACKdata" "MSBdata" "LSBdata" (1)Range : "0~2225" Zoom Target 0x46 0x00 "MSBdata" "LSBdata" 0x46 "ACKdata" "MSBdata" "LSBdata" Range : "0~1916" Focus/Zoom Concurrent Target 0x47 0x00 "zoomdata" "zoomLSB" 0x47 "focusdata" "focusLSB" "ACKdata" "zoomdata" "zoomLSB" (1)Focus : "0~2225" "ACKdata" "focusdata" "focusLSB" Zoom : "0~1916" (1)Drive Stop 0x2F 0x00 0x05 0x00 0x2D "ACKdata" 0x05 0x00 Depending of the zoom amount, the range of focus data will be changed. You can figure it out to see page 6. ("Focus-Status[Max]", "Focus-Status[Min]") Above 10 Command (Iris up/down ,Red up/down, Blue up/down, Focus far/near, Zoom tele/wide) will go to all the way once you execute it. "Drive Stop" can stop those command in certain point that you want. 5 5