Samsung WF361BVBEWR/A1 Trouble Shooting Guide User Manual Ver.1.0 (English, Fr - Page 17
Problem Checking And Method Of Pcb, Warning
View all Samsung WF361BVBEWR/A1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless testing requires power. PROBLEM CHECKING AND METHOD OF PCB - If you plug in the power cord and turn Power S/W on, memorized data is displayed. If any data is not displayed, check the followings. WF361*/WF363* WF365* Thermistor Check Check Voltage at Pin #1 and #2 of CN3 Tester Check = DC 2.7V If it ready 5V, check if its connector is engaged properly. Water Sensor Check Check Voltage and Frequency at Pin #3 and #2 of CN3 Reset water level = DC2.5V, 25.0KHz Check Voltage and Frequency at Pin #4 and #2 of CN3 Reset water level = DC2.5V, 25.0KHz 17 [BIGBANG]Technical_information-03207A_EN_20120531.indd 17 2012-05-31 �� 2:47:07