Sanyo PDG-DWL100 RS232C Expand - Page 32
PC Status Read Commands, CR_FSYNC Command, CR_TDOTS Command, CR_H-POS Command, CR_V-POS Command
UPC - 086483074875
View all Sanyo PDG-DWL100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
PDG-DWL100 Expand Serial Command Functional Specifications 9.5 PC Status Read Commands 9.5.1 CR_FSYNC Command Command "CR_FSYNC" [CR] Details Get value of Fine Sync Acceptable Correspondence %1 "000_%1" [CR] "0000-0031" ------ Directly specify setting value of Fine sync "Error Code" [CR When command is invalid in Unacceptable the given condition "?" [CR] --------- When unknown command is received 9.5.2 CR_TDOTS Command Command "CR_TDOTS" [CR] Details Get value of Total Dots Acceptable "000_%1" [CR] Correspondence %1 Unacceptable "-005" - " 0005" (nnnn = Display Dots + Horizontal Position) "Error Code" [CR] ---- When command is invalid in the given condition "?" [CR] --------- When unknown command is received 9.5.3 CR_H-POS Command Command "CR_H-POS" [CR] Details Get value of Horizontal Position Acceptable "000_%1" [CR] Correspondence %1 Unacceptable "-005" - " 0005" (nnnn = Total Dots - Display Dots) "Error Code" [CR] ---- When command is invalid in the given condition "?" [CR] --------- When unknown command is received 9.5.4 CR_V-POS Command Command "CR_V-POS" [CR] Details Get value of Vertical Position Acceptable "000_%1" [CR] Correspondence %1 Unacceptable "-005" - "0005" (nnnn = Total Line - Display Line) "Error Code" [CR] ---- When command is invalid in the given condition "?" [CR] --------- When unknown command is received 32 / 47