Sanyo PDG-DXL100 RS232C Expand - Page 47
CR_TEMP Command, Modification, CR_STATUS Command
UPC - 086483074868
View all Sanyo PDG-DXL100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
PDG-DXL100 Expand Serial Command Functional Specifications 9.12.7 CR_TEMP Command Command "CR_TEMP" [CR] Details Get the information about the temperature inside the projector (1) close to the abnormal 2) in the abnormal status 3) in the safe temperature level 4)abnormal status is not detected). Possible to get data from plural sensor s at once. Acceptable "000_%1" [CR] %1=Temperature of sensor1 %2=Temperature of sensor2 %1, %2 fixed 6 digits. Between %1 and %2 is space 1 character. "_31.5 " "_" means a space and "_" changes into "-", when temperature gets below freezing. e.g. -05.5F The last character shows if corresponding sensor is under abnormal temperature. Correspondence %1,%2,%3 "F" ------- Abnormal temperature "W"-------Close to abnormal temperature(Temperature is as high to display Warning) "S" -------Not close to abnormal temperature (Temperature is low enough and safe.) "N"-------Applicable sensor does not detect abnormal temperature "E" -------Not able to return temperature data When several sensors are incorporated, projector returns values continuously. Etc. "_31.5F__35.2S"[CR] A data of sensor 1 comes first and a data of sensor 2 follows after single space. As described respectively in e.g., sensor 1 detects abnormal temp., sensor 2 detects 35.2 degrees which means safe temperature. . In case projector cannot return its data due to some hard ware failure, the last character becomes "E" such as "_00.0E". Some of the projectors get abnormal temperature because of heat of Lamp ballast in Standby mode or Powering ON. Therefore detection of abnormal temperature is suspended while Standby mode or adequate time after Power ON, and during that time projector returns "_----N" as a temperature data. Unacceptable "?" [CR] 10 Modification Version Date 1.01 2009.7.31 Modification CR_STATUS Command "81" = Standby after Cooling Down due to lamp failure Delete 47 / 47