PDG-DXL2000 Expand Serial Command Functional Specifications 9.11.29 CR_FILREPL Command Command "CR_FILREPL"[CR] Details Get the information of Filter replacement time Acceptable "000_%1"[CR] Response %1 "1Y Over filter replacement time "1N Within filter replacement time Unacceptable "Error Code"[CR] 9.11.30 CR_FILTIMER Command Command "CR_FILTIMER" [CR] Details Get setting time which filter warning OSD is displayed Acceptable "000_%1"[CR] "2000 2000 hours Response %1 "3000 3000 hours "4000 4000 hours "OFF No OSD display Unacceptable "Error Code"[CR] 68/72
PDG-DXL2000
Expand Serial Command Functional Specifications
68/72
9.11.29 CR_FILREPL Command
Command
“CR_FILREPL”[CR]
Details
Get the information of Filter replacement time
Acceptable
“000_%1”[CR]
%1
“1Y” ------------------- Over filter replacement time
“1N” ------------------ Within filter replacement time
Response
Unacceptable
“Error Code”[CR]
9.11.30 CR_FILTIMER Command
Command
“CR_FILTIMER” [CR]
Details
Get setting time which filter warning OSD is displayed
Acceptable
“000_%1”[CR]
%1
“2000” -----------------2000 hours
“3000” -----------------3000 hours
“4000” -----------------4000 hours
“OFF” ---------------- No OSD display
Response
Unacceptable
“Error Code”[CR]