Sanyo PLC-HF15000L RS232 Expand

Sanyo PLC-HF15000L - 15000 Lumens Manual

Sanyo PLC-HF15000L manual content summary:

  • Sanyo PLC-HF15000L | RS232 Expand - Page 1
    EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-HF15000L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-HF15000L | RS232 Expand - Page 2
    PLC-HF15000L Expand Serial Command Functional Specifications CONTENTS 1 Overview ...10 2 Serial Interface Command Table 13 5.3 Input Control Command Table 14 5.4 Screen Command Table 14 5.5 Lamp Command Table 14 5.6 Setting Command Table 14 5.7 Other Command Table 16 6 Status Read
  • Sanyo PLC-HF15000L | RS232 Expand - Page 3
    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.11 CF_SHARP Command 24 8.4.12 CF_GAMMA Command 25 8.4.13 CF_NZRED Command 25 8.4.14 CF_PROGV Command 25 8.4.15 CF_IMAGE Command 26 8.4.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 4
    PLC-HF15000L Expand Serial Command Functional Specifications 8.8 Lamp Command...41 8.8.1 CF_LAMPMODE Command 41 8.8.2 CF_ LAMPCONSTTAR Command 41 8.8.3 CF_AUTOLAMPCONTRL Command 41 8.8.4 CF_LAMPLIFECONTRL Command 42 8.8.5 CF_LAMPINTERVAL Command 42 8.9 Setting Command ...43 8.9.1 CF_LANG
  • Sanyo PLC-HF15000L | RS232 Expand - Page 5
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.34 CF_CMSTORE Command 52 8.9.35 CF_CMMSTESTPAT Command 53 8.9.36 CF_CMTGTESTPAT Command 53 8.9.37 CF_CMFDEFAULT Command 53 8.9.38 CF_CMMENUOFF Command 53 8.9.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 6
    PLC-HF15000L Expand Serial Command Functional Specifications 9.1 Format...64 9.2 Transfer Example...64 9.3 Operation condition 64 9.4 Image Status Read Commands 65 9.4.1 CR_CONT Command 65 9.4.2 CR_BRIGHT Command 65 9.4.3 CR_COLOR
  • Sanyo PLC-HF15000L | RS232 Expand - Page 7
    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.5 CR_MODELIST Command 76 9.7.6 CR_SRCINP1 Command 76 9.7.7 Command 81 9.8.9 CR_HPOS Command 81 9.8.10 CR_SCREENASPECT Command 82 9.9 Lamp Status Read Commands 83 9.9.1 CR_LAMPREPL Command 83 9.9.2 CR_LAMPMODE Command 83
  • Sanyo PLC-HF15000L | RS232 Expand - Page 8
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.1 CR_LANG Command 86 9.10.2 CR_MENUSIZE Command 86 9.10.3 CR_DISP Command 86 9.10.4 CR_BACKGND Command 86 9.10.5 CR_PIP Command 87 9.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 9
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.41 CR_SHUTH Command 96 9.10.42 CR_SHUTEFFECT Command 96 9.10.43 CR_SHUTRELEASE Command 96 9.10.44 CR_DELAYCTRL Command 96 9.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 10
    defines communication for PLC-HF15000L. Most commands are also available to remote-control a projector through RS-232C from in Service Mode 2.2 Connection Dedicated serial cables that come with a projector must be used for the connection between a computer and the projector. PC Projector COM
  • Sanyo PLC-HF15000L | RS232 Expand - Page 11
    PLC-HF15000L Expand Serial Command Functional Specifications Expand Serial Command is defined as a single command per line that starts with "C" and ends with carriage return (0x0D). When a projector receives carriage return (0x0D), it starts decoding. There are two types of commands as below:
  • Sanyo PLC-HF15000L | RS232 Expand - Page 12
    PLC-HF15000L Expand Serial Command Functional Specifications 4 Notation Data from a controller to a projector is represented as COMMAND, and data from a projector to a controller in response to the incoming command is represented as RESPONSE. [CR]: Carriage Return Code The command ends with carriage
  • Sanyo PLC-HF15000L | RS232 Expand - Page 13
    PLC-HF15000L Expand Serial Command Functional Specifications 5 Functional Execution Command Table 5.1 Image Command Table Execute command CF_CONT_%1[CR] CF_BRIGHT_%1[CR] CF_COLOR_%1[CR] CF_TINT_%1[CR] CF_COLMNSAV_%1[CR] CF_COLMNLD_%1[
  • Sanyo PLC-HF15000L | RS232 Expand - Page 14
    PLC-HF15000L Expand Serial Command Functional Specifications 5.3 Input Control Command Table Scale Set V Position Set H Scale Set H Position Set Screen aspect function 5.5 Lamp Command Table Execute command CF_LAMPMODE_%1[CR] CF_LAMPCONSTTAR_%1 [CR] CF_AUTOLAMPCONTRL_%1[CR] CF_LAMPLIFECONTROL_%1[CR
  • Sanyo PLC-HF15000L | RS232 Expand - Page 15
    PLC-HF15000L status of "Picture in Picture" to User1-5 Delete the values registered in User %1 and return it to Free status. Reset setting of "Picture in cancel PJ lock Reset Filter used time Set time to display Filter cleaning / replacement warning on screen Schedule filter cleaning task Set the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 16
    PLC-HF15000L Expand Serial Command Functional Specifications CF_PTIME_%1[CR] CF_KEYDIS_%1[CR] CF_FDEFAULT_%1[CR] CF_SHUTRCPROT_%1[CR] CF_SHUTKEYPROT_%1[CR] CF_SHUTH_%1[CR] CF_SHUTEFFECT_%1[CR] CF_SHUTRELEASE_%1[CR] CF_DELAYCTRL_%1[CR] CF_CCAPTIONDISP_%1[CR]
  • Sanyo PLC-HF15000L | RS232 Expand - Page 17
    PLC-HF15000L Expand Serial Command Functional Specifications 6 Status Read Command Table 6.1 Image Status Read Command Table Status read command CR_CONT [CR] CR_BRIGHT [CR] CR_COLOR [CR] CR_TINT [CR]
  • Sanyo PLC-HF15000L | RS232 Expand - Page 18
    PLC-HF15000L Expand Serial Command Functional Specifications CR_SRCINP1 [CR] CR_SRCINP2 [CR] CR_SRCINP3 [CR] CR_SRCINP4 function level. CR_LAMPSTS [CR] Get Lamp lighting status CR_INFLAMP [CR] Get Lamp switching status CR_PROJH [CR] Get the projector total running time CR_HMLAMP [CR] Get
  • Sanyo PLC-HF15000L | RS232 Expand - Page 19
    PLC-HF15000L Expand Serial Command Functional Specifications 6.7 Setting Status Read Command ] Get Filter used time CR_FILCOND[CR] Get status of filter clog CR_FILREPL[CR] CR_FILTIMER[CR] CR_FILREMAIN[CR] Get status of Filter cleaning / replacement time Get time to display Filter cleaning
  • Sanyo PLC-HF15000L | RS232 Expand - Page 20
    PLC-HF15000L Expand Serial Command Functional Specifications CR_BLENDBLK[CR] CR_BLENDTESTPAT[CR] CR_COLORMATCHING[ Read Command Table Status read command Item CR_STATUS [CR] Get operation state of the projector CR_SIGNAL [CR] Get status of signal existence CR_VMUTE [CR] Get setting status of
  • Sanyo PLC-HF15000L | RS232 Expand - Page 21
    PLC-HF15000L Expand Serial Command Functional Specifications 8 Functional Execution Command 8.1 Format 1) PC issues a Code Table] "?" [CR]: When the received data cannot be decoded 8.2 Transfer Example When setting projector's total dots to 1344 by Expand Command. PC → PJ: "CF_TDOTS_1344" [CR] PC ←
  • Sanyo PLC-HF15000L | RS232 Expand - Page 22
    PLC-HF15000L Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_ CONT Contrast by 1 Details Set user controlled value of Contrast. (Available only in the normal Power ON status) The value set by this command is not stored in the projector. Therefore, when the power
  • Sanyo PLC-HF15000L | RS232 Expand - Page 23
    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.5 CF_COLMNSAV Command Command "CF_COLMNSAV_%1" [CR in the normal Power ON status) The value set by this command is not stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 24
    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.9 CF_WBAL- Command Command "CF_WBAL-%1_%2" [ by 1 Details Set user controlled value of Sharpness. (Available only in the normal Power ON status) The value set by this command is not stored in the projector's memory. Therefore, when
  • Sanyo PLC-HF15000L | RS232 Expand - Page 25
    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.12 CF_GAMMA Command Command "CF_GAMMA_%1" [CR] "000-015 Directly specify setting value of Gamma %1 "UP Increment setting value of Gamma by 1 "DN Decrement setting value of Gamma by 1 Details Set user in the projector's memory
  • Sanyo PLC-HF15000L | RS232 Expand - Page 26
    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.15 CF_IMAGE Command Command "CF_IMAGE__%1" by user) Details Select Image mode. (Valid only when it is in the normal Power ON status.) Parameter "CUSTOM1" to "CUSTOM10" corresponds to "Image1" to "Image10" displayed in projector OSD
  • Sanyo PLC-HF15000L | RS232 Expand - Page 27
    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.17 CF_ADVCOL Command Command "CF_ADVCOL_%1" [CR] in the normal Power ON status) The value set by this command is not stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 28
    PLC-HF15000L Expand Serial Command Functional Specifications 8.5 PC Control Command 8.5.1 CF_FSYNC Command Command in the normal Power ON status) The value set by this command is not stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 29
    PLC-HF15000L Expand Serial Command Functional Specifications 8.5.4 CF_V-POS Command Command "CF_V-POS_%1" [ only in the normal Power ON status) The value set by this command is not stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 30
    PLC-HF15000L Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command "CF_DLINE_%1" [CR] in the normal Power ON status) The value set by this command is not being stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 31
    PLC-HF15000L Expand Serial Command Functional Specifications 8.5.9 CF_PCSTORE Command Command "CF_PCSTORE_%1" [CR] "MODE1 Store current PC Adjust status to Mode1 "MODE2 Store current PC Adjust status to
  • Sanyo PLC-HF15000L | RS232 Expand - Page 32
    PLC-HF15000L Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command "CF_INPUT_%1" [ ON status.) This command works the same way as "INPUT" button of the projector and remote control. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR
  • Sanyo PLC-HF15000L | RS232 Expand - Page 33
    PLC-HF15000L Expand Serial Command Functional Specifications 8.6.3 CF_INPUT1~4 Command Command "CF_INPUT%1_%2" [CR] "1 Specify Input 1 %1 "2 Specify Input 2 "3 Specify Input 3 "4 Specify Input 4 "DIGITAL Select DVI Input (Computer signal) "
  • Sanyo PLC-HF15000L | RS232 Expand - Page 34
    PLC-HF15000L Expand Serial Command Functional Specifications Details Response Input is HDMI "D-XGA1 Select D-XGA1 : "D-WXGA3 Select D-WXGA3 "D-1080I Select D-1080i : "D-575p Select D-575p "D-480p Select D-480p
  • Sanyo PLC-HF15000L | RS232 Expand - Page 35
    PLC-HF15000L Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command "CF_SCREEN_%1" [CR] "NORMAL Select Normal mode "FULL Select Full mode "WIDE Select Wide (16:9)
  • Sanyo PLC-HF15000L | RS232 Expand - Page 36
    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command "CF_KEYSTONE _%1" [CR in the normal Power ON status). When reached the limit of the correction level, projector accepts the command but does not execute it. Receiving this command immediately invokes the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 37
    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.6 CF_CORNER-DL Command Command Available in normal Power ON status only) The correction starts with the first command received Projector returns error code ""101 and no operation is made when exceeding the correction limit.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 38
    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.10 CF_CEIL Command Command "CF_CEIL_%1" [CR] %1 "ON Set Ceiling to ON "OFF Set Ceiling to OFF Details Set/Cancel Ceiling. (
  • Sanyo PLC-HF15000L | RS232 Expand - Page 39
    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.13 CF_VPOS Command Command "CF_VPOS_%1" [CR] "015 15 "014 14 "001 1 "000 0 %1 " 01 1 Details Response " 14 14 " 15 15 "UP
  • Sanyo PLC-HF15000L | RS232 Expand - Page 40
    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.15 CF_HPOS Command Command "CF_HPOS_%1" [CR] "015 15 "014 14 "002 2 "001 1 "000 0 %1 " 01 1 " 02 2 " 14 14 " 15 15 "UP
  • Sanyo PLC-HF15000L | RS232 Expand - Page 41
    PLC-HF15000L Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPMODE Command Command "CF_LAMPMODE_%1" [CR] "4LAMP Set lamp mode to 4-lamps "3LAMPAUTO" ---- Set lamp mode to 3-lamps and automatically and preferentially use lamps with shorter cumulated lighting time.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 42
    PLC-HF15000L Expand Serial Command Functional Specifications 8.8.4 CF_LAMPLIFECONTRL Command Command "CF_LAMPLIFECONTRL_%1" [CR] %1 "MODE1 Set Lamp life control mode to Mode1 "MODE2 Set Lamp life control mode to Mode2 Details Select Lamp life control. (Valid only when in the normal Power ON
  • Sanyo PLC-HF15000L | RS232 Expand - Page 43
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9 Setting Command 8.9.1 CF_LANG Command Command "CF_LANG_%1" [CR] "ENG Select ENGLISH "DEU Select German "FRA Select French "ITA Select Italian "ESP
  • Sanyo PLC-HF15000L | RS232 Expand - Page 44
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.4 CF_DISP Command Command " in EEPROM and the setting remains even after the power is turned to ALL OFF status. *When 1="USER" is received, error code "101" is returned, in the case of Capture non-practice. Acceptable Response
  • Sanyo PLC-HF15000L | RS232 Expand - Page 45
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.8 CF_PIPMAININP Command Command "CF_PIPMAININP_%1_%2" [CR] "1 Select Input 1 %1 "2 Select Input 2 "3 Select Input 3 "4 Select Input 4 "DIGITAL Select DVI Input "ANALOG Select
  • Sanyo PLC-HF15000L | RS232 Expand - Page 46
    PLC-HF15000L Expand Serial Command Functional Specifications Details Response Select input and source of Sub picture of "Picture in Picture". (Valid only when in the normal Power
  • Sanyo PLC-HF15000L | RS232 Expand - Page 47
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.13 CF_PIPPOSITION User 1 "USER2"---- Store current setting status to User 2 %1 "USER3"---- Store current setting status to User 3 "USER4"---- Store current setting status to User 4 "USER5"---- Store current setting status to User
  • Sanyo PLC-HF15000L | RS232 Expand - Page 48
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.16 CF_PIPMODEFREE Command Command "CF_PIPMODEFREE_%1" [CR] "USER1 Set User1 to Free status "USER 2 Set User2 to Free status %1 "USER 3 Set User3 to Free status "USER 4 Set User4 to Free status "USER 5 Set User5 to Free
  • Sanyo PLC-HF15000L | RS232 Expand - Page 49
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.20 CF_BLENDSTART Command Command "CF_BLENDSTART_%1_%2" [CR] "LEFT Left side %1 "RIGHT Right side "TOP Upper side "BOTTOM Lower side "000"-"
  • Sanyo PLC-HF15000L | RS232 Expand - Page 50
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.23 CF_BLENDTESTPAT Command Command "CF_BLENDTESTPAT_%1" [CR] %1 "ON Set to On "OFF Set to Off Details Set Test pattern of Edge
  • Sanyo PLC-HF15000L | RS232 Expand - Page 51
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.28 CF_CMMSXY Command Command %1 "CF_CMMSXY_%1_%2_%3" [CR] "RED Set value of Red "GREEN Set value of Green "BLUE Set
  • Sanyo PLC-HF15000L | RS232 Expand - Page 52
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.31 CF_CMTGG Command Command "CF_CMTGG_%1_%2" [CR] "RED Set value of Red "GREEN Set value of Green "BLUE Set value
  • Sanyo PLC-HF15000L | RS232 Expand - Page 53
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.35 CF_CMMSTESTPAT Command Command "CF_CMMSTESTPAT_%1" [CR] "RED Display Red %1 "GREEN Display Green "BLUE Display Blue "OFF Do not show test
  • Sanyo PLC-HF15000L | RS232 Expand - Page 54
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.39 CF_CMMENU Command Command " Directly set Logo PIN code "OFF Cancel Logo display "DFLT Select Logo of Factory Default %2 "USER Select User "UP The same operation as pressing Up key or Left key "DN The same operation as
  • Sanyo PLC-HF15000L | RS232 Expand - Page 55
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.42 CF_FILCTL Command Command "CF_FILCTL_%1" [CR] %1 "SKD Schedule filter cleaning task Details Schedule filter cleaning Acceptable "000" [CR] Response Unacceptable "Error Code" [CR] 8.9.43 CF_FANSPEED Command Command "
  • Sanyo PLC-HF15000L | RS232 Expand - Page 56
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.46 CF_P-MANE Command Command "CF_P-MANE_%1" [CR] "OFF Set Power Management to Off "READY Set Power Management to Ready %1 "
  • Sanyo PLC-HF15000L | RS232 Expand - Page 57
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.50 CF_PJPINCODE Command Command "CF_PJPINCODE_ When PIN code lock is set to "On1", it needs to send this command every time the projector is turned on. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.51
  • Sanyo PLC-HF15000L | RS232 Expand - Page 58
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.54 CF_SHUTEFFECT Command Command "CF_SHUTEFFECT_%1" [CR] "OFF" --------Disable fade in and out function of Shutter %1 "L1" --------- Set fade in and
  • Sanyo PLC-HF15000L | RS232 Expand - Page 59
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.58 CF_CCAPTIONCOLOR Command Command "CF_CCAPTIONCOLOR Command Command "CF_FILH_%1" [CR] %1 "RST Reset Filter used time Details Reset used time for filter of projector Acceptable Response "000" [CR] Unacceptable "Error Code"
  • Sanyo PLC-HF15000L | RS232 Expand - Page 60
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.62 CF_ PTIMEMODE Command Command "CF_PTIMEMODE_%1" [CR] %1 "COUNTUP Set P-timer to Count up mode "COUNTDN Set P-timer to Count down
  • Sanyo PLC-HF15000L | RS232 Expand - Page 61
    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.66 CF_FDEFAULT Command Command "CF_FDEFAULT_%1" [CR] %1 "RST" Details Return the settings to Factory Default status (Valid only when in the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 62
    PLC-HF15000L "AUTOPC Execute Auto PC Adj. operation "LENSSHIFT" ----------Return the Lens to center position The same operation as Control Key. Auto PC CF_KEYEMU parameter - When User menu is displayed: function is carried out with having displayed User menu. - When User menu isn't displayed:
  • Sanyo PLC-HF15000L | RS232 Expand - Page 63
    PLC-HF15000L Expand Serial Command Functional Specifications 8.10.3 CF_POWER Command Command "CF_POWER_%1" [CR] "ON Power ON "OFF Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. * Error Code is returned in some projector statuses,
  • Sanyo PLC-HF15000L | RS232 Expand - Page 64
    PLC-HF15000L Expand Serial Command Functional Specifications 9 Status Read Command 9.1 Format 1) PC issues a command in the format below: "CR_Command" [CR] Command: String 2) When the projector receives the applicable command, it returns the required information as a data string. "000_" %1 [CR] %1:
  • Sanyo PLC-HF15000L | RS232 Expand - Page 65
    PLC-HF15000L Expand Serial Command Functional Specifications 9.4 Image Status Read Commands 9.4.1 CR_CONT Command Command "CR_CONT" [CR] Details Get user controlled value of Contrast Acceptable Response %1 "000_%1" [CR] "000" - "063" Unacceptable "?" [CR] 9.4.2 CR_BRIGHT Command Command "
  • Sanyo PLC-HF15000L | RS232 Expand - Page 66
    PLC-HF15000L Expand Serial Command Functional Specifications 9.4.6 CR_COLTEMP Command Command "CR_COLTEMP" [CR] High) Unacceptable "?" [CR] 9.4.7 CR_WBAL-R Command Command "CR_WBAL-R" [CR] Details Get user controlled Red value of White Balance Acceptable "000_%1" [CR] Response %1 "000" -
  • Sanyo PLC-HF15000L | RS232 Expand - Page 67
    PLC-HF15000L Expand Serial Command Functional Specifications 9.4.12 CR_OFFSET-B Command Command "CR_OFFSET-B" [CR] Details Get user controlled Blue [CR] 9.4.13 CR_SHARP Command Command "CR_SHARP" [CR] Details Get user controlled value of Sharpness Acceptable Response %1 "000_%1" [CR] "000"
  • Sanyo PLC-HF15000L | RS232 Expand - Page 68
    PLC-HF15000L Expand Serial Command Functional Specifications 9.4.17 CR_IMAGE Command Command "CR_IMAGE" [CR] Details Get image setting status. The Required data "CUSTOM1" - "CUSTOM10" corresponds to "Image1" - "Image10"
  • Sanyo PLC-HF15000L | RS232 Expand - Page 69
    PLC-HF15000L Expand Serial Command Functional Specifications 9.5 PC Status Read Commands 9.5.1 CR_FSYNC Command Command "CR_FSYNC" [CR] Details Get value of Fine Sync Acceptable Response %1 "000_%1" [CR] "0000" - "
  • Sanyo PLC-HF15000L | RS232 Expand - Page 70
    PLC-HF15000L Expand Serial Command Functional Specifications 9.5.5 CR_CLAMP Command Command "CR_CLAMP" [CR] Details Get value of Clamp Acceptable "000_%1" [CR] Response %1 Unacceptable "0000" - " 4095" "Error Code" [CR
  • Sanyo PLC-HF15000L | RS232 Expand - Page 71
    PLC-HF15000L Expand Serial Command Functional Specifications 9.5.8 CR_ORGMODE Command Command "CR_ORGMODE" [CR] Details Get the original signal of current selected Mode that is set in PC Adj.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 72
    PLC-HF15000L Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command "CR_SERSYS" [CR] Details Get currently selected signal. Value only when Input is video. (
  • Sanyo PLC-HF15000L | RS232 Expand - Page 73
    PLC-HF15000L Expand Serial Command Functional Specifications 9.7 Input Read Command 9.7.1 CR_INPUT Command Command "CR_INPUT" [CR] Details Get selected INPUT No. Acceptable Response %1 "000_%1" [CR] "1" - "4" Unacceptable "?" [CR] 9.7.2 CR_SOURCE
  • Sanyo PLC-HF15000L | RS232 Expand - Page 74
    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.3 CR_SYSTEM Command Command "CR_SYSTEM" [CR] Details Get selected System Response Acceptable "000_%1" [CR] "VGA1 indicates VGA1 is selected "VGA2 indicates
  • Sanyo PLC-HF15000L | RS232 Expand - Page 75
    PLC-HF15000L Expand Serial Command Functional Specifications Input is Video or S-video "AUTO indicates Auto is selected "NTSC indicates NTSC is selected "NTSC443 indicates NTSC4.43 is
  • Sanyo PLC-HF15000L | RS232 Expand - Page 76
    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.5 CR_MODELIST Command Command "CR_MODELIST" [CR] Details Get possible modes for Mode list Acceptable "000_%1_%2_---_%x" [CR] Error Code "101"
  • Sanyo PLC-HF15000L | RS232 Expand - Page 77
    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.8 CR_SRCINP3 Command Command "CR_SRCINP3" [CR] Input2/ New Video board Response %1 "HDCP-DVI2 New HDCP & DVI board "DUAL-SDI HD&SD-SDI board "DUALLINK-SDI Dual-Link SDI board "NOTERMINAL There is no board inserted
  • Sanyo PLC-HF15000L | RS232 Expand - Page 78
    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.13 CR_NMSLOT3 Command Command "CR_NMSLOT3" [CR] Details Get the board name inserted to Slot 3 Acceptable Response %1 "000_%1" [CR] The same
  • Sanyo PLC-HF15000L | RS232 Expand - Page 79
    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.17 CR_IDSLOT3 Command Command "CR_IDSLOT3" [CR] Details Get ID information on Slot 3. This command is to recognize the inserted slot
  • Sanyo PLC-HF15000L | RS232 Expand - Page 80
    PLC-HF15000L Expand Serial Command Functional Specifications 9.8 Screen Status Read Commands 9.8.1 CR_SCREEN Command Command "CR_SCREEN" [CR] Details Get currently selected screen image size Acceptable "000_%1" [CR] "NORMAL
  • Sanyo PLC-HF15000L | RS232 Expand - Page 81
    PLC-HF15000L Expand Serial Command Functional Specifications 9.8.5 CR_REAR Command Command "CR_REAR" [CR] Details Get setting status of Rear function Acceptable "000_%1" [CR] Response %1 "ON Rear projection is
  • Sanyo PLC-HF15000L | RS232 Expand - Page 82
    PLC-HF15000L Expand Serial Command Functional Specifications 9.8.10 CR_SCREENASPECT Command Command "CR_SCREENASPECT"[CR] Details Get status of Screen aspect Acceptable "000_%1" [CR] "FULL" Select Full screen mode
  • Sanyo PLC-HF15000L | RS232 Expand - Page 83
    PLC-HF15000L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Commands 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL" [CR] Details Get the information of Lamp Replacement time Acceptable "000_%1" [CR] "4****" 4 indicates 4 lamps are used in this model. indicates the
  • Sanyo PLC-HF15000L | RS232 Expand - Page 84
    PLC-HF15000L Expand Serial Command Functional Specifications 9.9.5 CR_AUTOLAMPCONTRL Command Command "CR_AUTOLAMPCONTRL" [CR] Details Get selected Lamp control mode Acceptable "000_%1" [CR] "NORMAL NORMAL is selected. Response %1 "ECO1 ECO1 is selected. "ECO2 ECO2 is selected. "AUTO
  • Sanyo PLC-HF15000L | RS232 Expand - Page 85
    PLC-HF15000L Expand Serial Command Functional Specifications 9.9.10 CR_LAMPH Command Command "CR_LAMPH" [CR] Details Get Lamp running time (in hours) * return actual lamp running time Acceptable "000_%1_%2_%3_%4" [CR] Response %1_%2 %3_%4 Lamp 1 data comes first, and then one space, after
  • Sanyo PLC-HF15000L | RS232 Expand - Page 86
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10 Setting Status Read Commands 9.10.1 CR_LANG Screen for no signal Acceptable "000_%1" [CR] "BLUE Blue Back is selected Response %1 "USER User is selected "BLACK Black Back is selected Unacceptable "Error Code" [CR] 86/105
  • Sanyo PLC-HF15000L | RS232 Expand - Page 87
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.5 CR_PIP Command Command "CR_PIP" [CR] Details Get setting status of "Picture in Picture" Acceptable "000_%1" [CR] "OFF Off is selected "USER1 User1 is selected Response %1 "USER2 User 2 is selected "USER3 User3 is
  • Sanyo PLC-HF15000L | RS232 Expand - Page 88
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.8 CR_PIPMAININP Command Command "CR_PIPMAININP" [CR] Details Get Input and Source of "Picture in Picture". (Main picture) Acceptable "000_%1_%2" [
  • Sanyo PLC-HF15000L | RS232 Expand - Page 89
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.10 CR_PIPSIZE Command Command "CR_PIPSIZE" [CR] Details Get picture size of "Picture in Picture". (Sub picture) Acceptable "000_%1_%2" [
  • Sanyo PLC-HF15000L | RS232 Expand - Page 90
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.14 CR_BLEND Command Command "CR_BLEND" [CR] Details Get all values set for Width in Edge blending Acceptable "000_%1_%
  • Sanyo PLC-HF15000L | RS232 Expand - Page 91
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.17 CR_BLENDTESTPAT Command Command "CR_BLENDTESTPAT" [CR] Details Get setting status of Test pattern of Edge blending Acceptable "000_%1" [CR]
  • Sanyo PLC-HF15000L | RS232 Expand - Page 92
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.21 CR_CMTGXY_%1 Command Command "CR_CMMTGXY_%1" [CR] Details Get "x""y" value of Target of Color matching Acceptable "000_%2" [CR] "RED value
  • Sanyo PLC-HF15000L | RS232 Expand - Page 93
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.25 CR_CMTGTESTPAT Command Command " setting status Acceptable "000_%1" [CR] "DFLT Default Logo is enabled Response %1 "USER User is enabled "OFF Off is enabled Unacceptable "?" [CR] 9.10.28 CR_LOGOLOCK Command
  • Sanyo PLC-HF15000L | RS232 Expand - Page 94
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.30 CR_RCODE Command Command "CR_RCODE" of projector "FRONT" ----- Select only front receiver of projector "TOP" --------- Select only top receiver of projector "BACK" ------- Select only back receiver of projector Unacceptable
  • Sanyo PLC-HF15000L | RS232 Expand - Page 95
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.35 CR_KEYDIS Command Command "CR_KEYDIS" [CR] Details Get setting status of RC/KEY use limitation (valid or invalid) Acceptable "
  • Sanyo PLC-HF15000L | RS232 Expand - Page 96
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.40 CR_SHUTKEYPROT Command Command "CR_SHUTKEYPROT" [CR] Details Get status if Shutter can be controlled by key on the side
  • Sanyo PLC-HF15000L | RS232 Expand - Page 97
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.45 CR_CCAPTIONSIDP Command Command "CR_CCAPTIONDISP" [ Error Code" [CR] 9.10.47 CR_FILH Command Command "CR_FILH" [CR] Details Get Filter used time Acceptable "000_%1" [CR] Response %1 "00000 - 99999" Unacceptable "Error Code
  • Sanyo PLC-HF15000L | RS232 Expand - Page 98
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.50 CR_FILREMAIN Command Command "CR_FILREMAIN" [CR] Details Get the value of Filter counter remaining (remaining life time of the air filter) (%). Acceptable "000_%1" [CR] "100" = Filter counter remaining is 100% Response %1 "
  • Sanyo PLC-HF15000L | RS232 Expand - Page 99
    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.55 CR_PTIME Command Command "CR_PTIME" [CR] Details Get setting time for count down mode of P-timer Response Acceptable %1 "000_%a" [
  • Sanyo PLC-HF15000L | RS232 Expand - Page 100
    PLC-HF15000L Expand Serial Command Functional Specifications 9.11 Other Status Read Commands 9.11.1 CR_STATUS Command Command "CR_STATUS" [CR] Details Get operating status of Projector after turned Off due to lamp failure "81" = Standby after Cooling Down due to lamp failure "2C" = Cooling
  • Sanyo PLC-HF15000L | RS232 Expand - Page 101
    PLC-HF15000L Expand Serial Command Functional Specifications 9.11.5 CR_TEMPFAIL Command Command "CR_TEMPFAIL" [CR] Details Get the temperature inside the projector when the abnormal status occurs. It is possible to get the temperatures for more than one sensor all at once if it is applicable.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 102
    PLC-HF15000L Expand Serial Command Functional Specifications 9.11.6 CR_TEMP Command Command "CR_TEMP"[CR] Details Get the current temperature information inside a projector happen for some projectors that the temperature continues to go up to abnormal status as long as lamp ballasts are hot.
  • Sanyo PLC-HF15000L | RS232 Expand - Page 103
    PLC-HF15000L Expand Serial Command Functional Specifications 9.11.9 CR_SERIALNO Command Command "CR_SERIALNO" [CR] Details Get value of the serial number. For Dealer Acceptable Response %1 "000_%1" [CR] Eight digits of alphanumeric characters Unacceptable "?" [CR] 103/105
  • Sanyo PLC-HF15000L | RS232 Expand - Page 104
    PLC-HF15000L Expand Serial Command Functional Specifications 10 Command with Address Specification 10.1. Overview - Commands with address are used to remote control more than one projector "A001CR0" [CR] - Projector has the function to set up its own address in Service mode. Initial setting value is
  • Sanyo PLC-HF15000L | RS232 Expand - Page 105
    PLC-HF15000L Expand Serial Command Functional Specifications 10.2.2. When the number ("001" - "999") Command: string (Refer to Basic and Expand Serial Commands) 2) The only projectors that have the address matching with the one in the received data decode the command, and it returns required
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-HF15000L
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division