    BASIC SERIAL COMMAND SPECIFICATIONS PLC-XU4000 Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-XU4000 | RS232 Basic - Page 2
    PLC-XU4000 Basic Serial Command Specifications CONTENTS 1. Overview ...3 2. Serial Interface Specifications 3 2.1. Transfer Specifications 3 2.2. Connection ...3 3. Notes for Communication 4 4. Functional Execution Command Table 5 5. Status Read Command Table 7 6. Functional Execution
  • Sanyo PLC-XU4000 | RS232 Basic - Page 3
    PLC-XU4000 Basic Serial Command Specifications 6.32. BRIGHTNESS - Command 14 6.33. IMAGE (Toggle) Command Example 19 7.3. Operation Requirements 19 7.4. Status Read Command 19 7.5. Input Mode Read Command 22 7.6. Lamp Time Read Command 22 7.7. Setting Read Command 22 7.8. Temp Read Command 22
  • Sanyo PLC-XU4000 | RS232 Basic - Page 4
    projector control commands for PLC-XU4000. 1.2. The projector control commands are used to remotely control a projector can be changed in service mode. 2.2. Connection Dedicated serial cable must be used for connection to a computer and a projector. PC COM 1 Projector Control Port (D-Sub
  • Sanyo PLC-XU4000 | RS232 Basic - Page 5
    PLC-XU4000 Basic Serial Command Specifications 3. Notes for Communication 1. The projector control command is defined as one it takes more than one second to receive carriage return (0x0D) after the projector receives the first data "C". 4. For Command pipelining, wait for the interval of
  • Sanyo PLC-XU4000 | RS232 Basic - Page 6
    PLC-XU4000 Basic Serial Command Specifications 4. Functional Execution Command Table Command Item C00 POWER ON C01 POWER OFF (Quick Power OFF) C02 POWER OFF C03 ――― C04 ――― C05
  • Sanyo PLC-XU4000 | RS232 Basic - Page 7
    PLC-XU4000 Basic Serial Command Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53
  • Sanyo PLC-XU4000 | RS232 Basic - Page 8
    PLC-XU4000 Basic Serial Command Specifications 5. Status Read Command Table Command Item CR0 CR1 CR2 Status Read Input Mode Read ――― CR3 (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read CR7 Lamp Mode Read ――― means no function. Memo 7/23
  • Sanyo PLC-XU4000 | RS232 Basic - Page 9
    PLC-XU4000 Basic Serial Command Specifications 6. Functional Execution Command 6.1. Format 6.1.1 PC issues a command in format as below. "C" COMMAND [CR] Command: two characters (See Basic Functional Execution Command Table) A projector changes received data to decode and returns a result after
  • Sanyo PLC-XU4000 | RS232 Basic - Page 10
    PLC-XU4000 Basic Serial Command Specifications 6.4. Operation Requirements When the projector's status is any of below, Functional Execution Commands are limited. Projector Status In Standby Countdown in process Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal Temperature
  • Sanyo PLC-XU4000 | RS232 Basic - Page 11
    PLC-XU4000 Basic Serial Command Specifications 6.5. POWER ON Command Command "C00" [ Detail Power OFF (Standby). The command operates the same Power OFF function as ON/STAND-BY button of the projector and remote control. Once this command is sent, "Power OFF?" is displayed. If this command is sent
  • Sanyo PLC-XU4000 | RS232 Basic - Page 12
    PLC-XU4000 Basic Serial Command Specifications 6.10. Video Command Command "C07" [CR] Detail Select Video Input Although projector returns "OK", Input search is not executed with this command while Input search is set to On1 or On2, Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.
  • Sanyo PLC-XU4000 | RS232 Basic - Page 13
    PLC-XU4000 Basic Serial Command Specifications 6.15. VIDEO MUTE ON Command Command "C0D"[CR] Detail Video Mute ON. This command works the same way as "NO SHOW"
  • Sanyo PLC-XU4000 | RS232 Basic - Page 14
    PLC-XU4000 Basic Serial Command Specifications 6.21. Image Cinema Command Command "C13" [CR] Detail Set image to Cinema mode. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.22. Image1
  • Sanyo PLC-XU4000 | RS232 Basic - Page 15
    PLC-XU4000 Basic Serial Command Specifications 6.28. MENU ON Command Command "C1C" [CR] Detail Display On-Screen Display Menu. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.29. MENU
  • Sanyo PLC-XU4000 | RS232 Basic - Page 16
    PLC-XU4000 Basic Serial Command Specifications 6.34. Direct on Setting Command Command "C28" [CR] Detail Enable Direct on function. This status is stored in EEPROM and retained
  • Sanyo PLC-XU4000 | RS232 Basic - Page 17
    PLC-XU4000 Basic Serial Command Specifications 6.40. D.ZOOM - Command Command "C31" of On-Screen Display Menu to the right. This command works differently from the pointer ">" of the projector and remote control, and has no function of Volume +. Acceptable Response [ACK] [CR] Unacceptable "
  • Sanyo PLC-XU4000 | RS232 Basic - Page 18
    PLC-XU4000 Basic Serial Command Specifications 6.46. POINTER DOWN Command Command "C3D" [CR] Detail Move down the Pointer of On-Screen Display Menu. This command works the same way as the pointer "▼" of the projector. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.47. ENTER Command
  • Sanyo PLC-XU4000 | RS232 Basic - Page 19
    PLC-XU4000 Basic Serial Command Specifications 6.52. Computer 1 Component Command Command "C54" [CR] Detail Select Component input in Computer 1. Although projector returns "OK", Input search is not executed with this command while Input search is set to On1 or On2, Acceptable Response [ACK] [
  • Sanyo PLC-XU4000 | RS232 Basic - Page 20
    PLC-XU4000 Basic Serial Command Specifications 7. Status Read Command 7.1. Format 7.1.1. PC issues commands in format as below; "CR" Command [CR] Command 1 character(See Basic Status Read Command Table) 7.1.2. When a projector Power off due to lamp failure "81" = Standby after Cooling Down due to
  • Sanyo PLC-XU4000 | RS232 Basic - Page 21
    PLC-XU4000 Basic Serial Command Specifications [Details of Response] "00" [CR] Status : time depends on a model. This function is used to cool down the lamps and other optical parts and is quite important for projector's reliability. During this time, Functional Execution Commands are invalid. "10"
  • Sanyo PLC-XU4000 | RS232 Basic - Page 22
    PLC-XU4000 Basic Serial Command Specifications information of temperature anomaly is canceled in process after turned off due to lamp failure When a projector is turned off because of lamp failure, it automatically starts Cooling Down operation, in which the projector returns "21" [CR]. "81" CR
  • Sanyo PLC-XU4000 | RS232 Basic - Page 23
    PLC-XU4000 Basic Ceiling ON) Unacceptable "?" [CR] 7.8.Temp Read Command Command "CR6" [CR] Detail Get the temperature data inside the projector. With some temperature sensors installed in the projector can be returned due to hardware %3 problems, the first character becomes "E" like"E00
  • Sanyo PLC-XU4000 | RS232 Basic - Page 24
    PLC-XU4000 Basic Serial Command Specifications 7.9.Lamp Mode Read Command Command "CR7" [CR] Detail Get lamp mode status. For 1 lamp projector, get if it is lighting or not. Acceptable "%1" [CR] Response %1 "00" [CR]=Light is out. "01" [CR]=Light is on. Unacceptable " "[CR] 23/23