Schwinn 220 Recumbent Bike Assembly and Owner's Manual - Page 37

Check RPM Sensor re

Page 37 highlights

Dry or calloused hands Handlebars Console displays "E2" error Check data cable integrity code Check data cable connections/orientation Console Electronics No speed/RPM reading, Check data cable integrity Console displays "E3" error code Check data cable connections/orientation Check magnet position (requires shroud removal) Check RPM Sensor (requires shroud removal) Console shuts off (enters Check data cable integrity sleep mode) while in use Sensors may have difficulty with dried out or calloused hands. A conductive electrode cream such as "Signa Crème" or "Buh-Bump" can help make better conduct. These are available on the web or at medical or some larger fitness stores. If tests reveal no other issues, Handlebars should be replaced. All wires in cable should be intact. If any are cut or crimped, replace cable. Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. If tests reveal no other issues, Console should be replaced. All wires in cable should be intact. If any are cut or crimped, replace cable. Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Magnet should be in place on pulley. RPM sensor should be aligned with magnet and connected to data cable. Realign sensor if necessary. Replace if there is any damage to the sensor or the connecting wire. All wires in the cable should be intact. If any are cut or crimped, replace cable. 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

37
Dry or calloused hands
Sensors may have difficulty with dried
out or calloused hands. A conduc-
tive electrode cream such as “Signa
Crème” or “Buh-Bump” can help make
better conduct. These are available on
the web or at medical or some larger
fitness stores.
Handlebars
If tests reveal no other issues, Handle-
bars should be replaced.
Console displays “E2” error
code
Check data cable integrity
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Console Electronics
If tests reveal no other issues, Console
should be replaced.
No speed/RPM reading,
Console displays “E3” error
code
Check data cable integrity
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Check magnet position
(requires shroud removal)
Magnet should be in place on pulley.
Check RPM Sensor (re-
quires shroud removal)
RPM sensor should be aligned with
magnet and connected to data cable.
Realign sensor if necessary. Replace if
there is any damage to the sensor or
the connecting wire.
Console shuts off (enters
sleep mode) while in use
Check data cable integrity
All wires in the cable should be intact. If
any are cut or crimped, replace cable.