Seagate ST3000DM001 Barracuda 7200.9 SATA Product Manual - Page 38

Description, Value

Page 38 highlights

Word 60-61 62 63 64 65 66 67 68 69-74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 92 93 95-99 100- 103 Description Total number of user-addressable LBA sectors available (see Section 2.2 for related information) *Note: The maximum value allowed in this field is: 0FFFFFFFh (268,435,455 sectors, 137 Gbytes). Drives with capacities over 137 Gbytes will have 0FFFFFFFh in this field and the actual number of useraddressable LBAs specified in words 100-103. This is required for drives that support the 48-bit addressing feature. Retired Multiword DMA active and modes supported (see note following this table) Advanced PIO modes supported (modes 3 and 4 supported) Minimum multiword DMA transfer cycle time per word (120 nsec) Recommended multiword DMA transfer cycle time per word (120 nsec) Minimum PIO cycle time without IORDY flow control (240 nsec) Minimum PIO cycle time with IORDY flow control (120 nsec) ATA-reserved Queue depth Serial ATA capabilities Reserved for future Serial ATA definition Serial ATA features supported Serial ATA features enabled Major version number Minor version number Command sets supported Command sets supported Command sets support extension Command sets enabled Command sets enabled Command sets enable extension Ultra DMA support and current mode (see note following this table) Security erase time Enhanced security erase time Master password revision code Hardware reset value (see description following this table) ATA-reserved Total number of user-addressable LBA sectors available (see Section 2.2 for related information). These words are required for drives that support the 48-bit addressing feature. Maximum value: 0000FFFFFFFFFFFFh. Value ST3160811AS = 0FFFFFFFh* ST3160811AS = 0FFFFFFFh* ST3120811AS = 234,441,648 ST3120211AS = 234,441,648 ST380811AS = 156,301,488 ST380211AS = 156,301,488 ST340211AS = 78,165,360 0000H xx07H 0003H 0078H 0078H 00F0H 0078H 0000H 0000H xxxxH xxxxH xxxxH xxxxH 003EH 0000H 364BH 7C03H 4003H 30xxH 0001H 4000H xx3FH 0000H 0000H FFFEH xxxxH 0000H ST3160812AS = 312,581,808 ST3160212AS = 312,581,808 ST3120813AS = 234,441,648 ST3120213AS = 234,441,648 ST380811AS = 156,301,488 ST380211AS = 156,301,488 ST340211AS = 78,165,360 32 Barracuda 7200.9 Serial ATA Product Manual, Rev. C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

32
Barracuda 7200.9 Serial ATA Product Manual, Rev. C
60–61
Total number of user-addressable LBA sectors available
(see Section 2.2 for related information)
*Note: The maximum value allowed in this field is: 0FFFFFFFh
(268,435,455 sectors, 137 Gbytes). Drives with capacities over 137
Gbytes will have 0FFFFFFFh in this field and the actual number of user-
addressable LBAs specified in words 100-103. This is required for drives
that support the 48-bit addressing feature.
ST3160811AS = 0FFFFFFFh*
ST3160811AS = 0FFFFFFFh*
ST3120811AS = 234,441,648
ST3120211AS = 234,441,648
ST380811AS = 156,301,488
ST380211AS = 156,301,488
ST340211AS = 78,165,360
62
Retired
0000
H
63
Multiword DMA active and modes supported (see note following this
table)
xx
07
H
64
Advanced PIO modes supported (modes 3 and 4 supported)
0003
H
65
Minimum multiword DMA transfer cycle time per word (120 nsec)
0078
H
66
Recommended multiword DMA transfer cycle time per word (120 nsec)
0078
H
67
Minimum PIO cycle time without IORDY flow control (240 nsec)
00F0
H
68
Minimum PIO cycle time with IORDY flow control (120 nsec)
0078
H
69–74
ATA-reserved
0000
H
75
Queue depth
0000
H
76
Serial ATA capabilities
xxxx
H
77
Reserved for future Serial ATA definition
xxxx
H
78
Serial ATA features supported
xxxx
H
79
Serial ATA features enabled
xxxx
H
80
Major version number
003E
H
81
Minor version number
0000
H
82
Command sets supported
364B
H
83
Command sets supported
7C03
H
84
Command sets support extension
4003
H
85
Command sets enabled
30
xx
H
86
Command sets enabled
0001
H
87
Command sets enable
extension
4000
H
88
Ultra DMA support and current mode (see note following this table)
xx
3F
H
89
Security erase time
0000
H
90
Enhanced security erase time
0000
H
92
Master password revision code
FFFE
H
93
Hardware reset value
(see description following this table)
xxxx
H
95–99
ATA-reserved
0000
H
100–
103
Total number of user-addressable LBA sectors available (see Section 2.2
for related information). These words are required for drives that support
the 48-bit addressing feature. Maximum value: 0000FFFFFFFFFFFFh.
ST3160812AS = 312,581,808
ST3160212AS = 312,581,808
ST3120813AS = 234,441,648
ST3120213AS = 234,441,648
ST380811AS = 156,301,488
ST380211AS = 156,301,488
ST340211AS = 78,165,360
Word
Description
Value