Seagate ST980310AS Momentus 5400.5 SATA Product Manual - Page 38
Note., Table 8, Set Features command values
UPC - 890552649174
View all Seagate ST980310AS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Table 8: Set Features command values 45H Ultra DMA mode 5 46H Ultra DMA mode 6 55H Disable read look-ahead (read cache) feature. 82H Disable write cache AAH Enable read look-ahead (read cache) feature (default). C1H Disable the Free Fall Protection feature (41H above enables the Free Fall Protection feature) F1H Report full capacity available Note. At power-on, or after a hardware or software reset, the default values of the features are as indicated above. 30 Momentus 5400.5 SATA Product Manual, Rev. B
30
Momentus 5400.5 SATA Product Manual, Rev. B
Note.
At power-on, or after a hardware or software reset, the default values of the features are as indi-
cated above.
45
H
Ultra DMA mode 5
46
H
Ultra DMA mode 6
55
H
Disable read look-ahead (read cache) feature.
82
H
Disable write cache
AA
H
Enable read look-ahead (read cache) feature
(default).
C1
H
Disable the Free Fall Protection feature (41
H
above enables the Free Fall Protection feature)
F1
H
Report full capacity available
Table 8:
Set Features command values