Sharp ER-A440 Instruction Manual - Page 27
Currency exchange rate, High amount lockout HALO, Programming for the, Programming for exchange keys
View all Sharp ER-A440 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
6 Programming for exchange keys Currency exchange rate (e) PGM 1 PGM 2 Procedure To keep the current setting [ " through * Exchange rate : ; * Currency exchange rate: 0.000000 - 999.999999 Note You must use a decimal point when setting conversion rates that are fractional. Example [ Assigning 0.6068 to the key Key operation [ 0 . 6068 : ; Print Exchange rate 7 Programming for the Å , r , p , ' and î keys High amount lockout (HALO) (Å , r , p , ' and î) PGM 2 Procedure To keep the current setting Corresponding key *A B ≈; * AB is the same as A x 10B A: Significant digit (1 through 9) B: Number of zeros to follow the significant digit (0 through 8) Example } Programming a HALO limit of 1000.00 (15) for the key Key operation Print } 15 ≈ ; HALO limit 25