Sharp R-230HW Service Manual - Page 19
Procedure, Letter, Component Test
View all Sharp R-230HW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
PROCEDURE LETTER TEST PROCEDURES COMPONENT TEST R-203HW R-220HW R-230HW STEPS 1 2 OCCURRENCE Only pattern at "a" is broken. Pattern at "a" and "b" are broken. CAUSE OR CORRECTION *Insert jumper wire J1 and solder. *Insert the coil RCILF2003YAZZ between "c" and "d". 5) Make a visual inspection of the varistor. Check for burned damage and examine the transformer with a tester for the presence of layer short-circuit (check the primary coil resistance which is approximately 915Ω ± 10%). If any abnormal condition is detected, replace the control unit. VRS1 RY1 RY2 CN-A 3 1 ad c (J1) b T1 6) Reconnect all leads removed from components during testing. 7) Re-install the outer case (cabinet). 8) Reconnect the power supply cord after the outer case is installed. 9) Run the oven and check all functions. 2. Follow the troubleshooting guide given below, if indicator does not light up after above check and repairs are finished. 1) Disconnect the power supply cord and then remove outer case. 2) Open the door and block it open. 3) Discharge high voltage capacitor. 4) Disconnect the leads to the primary of the power transformer. 5) Ensure that these leads remain isolated from other components and oven chassis by using insulation tape. 6) After that procedure, re-connect the power supply cord. 7) Follow the troubleshooting guide given below for repair. STEPS OCCURRENCE CAUSE OR CORRECTION The rated AC voltage is not present between 1 Pin No. 3 of the 2-pin connector (A) and the Check supply voltage and oven power cord. normal open terminal of the relay RY2. The rated AC voltage is present at primary Low voltage transformer or secondary circuit defective. 2 side of low voltage transformer. Check and replace control unit. 8) Disconnect the power supply cord and then remove outer case. 9) Open the door and block it open. 10) Discharge high voltage capacitor. 11) Reconnect all leads removed from components during testing. 12) Re-install the outer case (cabinet). 13) Reconnect the power supply cord after the outer case is installed. 14) Run the oven and check all functions. 17