Sharp XE-A203 Programming Guide - Page 21

<CANCEL OPERATION&gt, <Programming for PLU.&gt, PROGRAMMING FOR -., PROGRAMMING FOR %.

Page 21 highlights

KEY ENTRY [PLU5] ->[00] ->COFFEE ->[ST] -> ->200 ->[ST] -> ->[CL] ->[CL] OPERATER 1234567890123456 NOTE PLU . 0005 0005 PLU1 TEXT / PLU CODE ENTER [ 00 ] KEY ENTER [00]-KEY TO CHANGE TEXT ENTER TEXT Message of "ENTER TEXT" is displayed. PLU . 0005 COFFEE _ PR I CE Guidance message 100 200 ENTER DEPT# PRICE IS DECIDED 01 01 0 . 00 PLU5 SET UP TERMINATE In this case, price(200) and text (COFFEE) are not written to the preset memory. KEY ENTRY [PLU1] ->[00] ->066 ->[00] ->EER ( is set space) ->[ST] -> ->200 ->[ST] ->01 ->[ST] -> -> [00] -> [00] ->[ST] ->[TL] OPERATER 1234567890123456 NOTE PLU . 0001 0001 PLU1 TEXT / PLU CODE ENTER [00 ] KEY ENTER TEXT Message of "ENTER TEXT" is displayed. PLU. 0001 Current PLU1 text is displayed. Then the cursor is blinking. (*) 066 Text code is inputted. BLU. 0001 If [00] key is entered and inputted text is addressed. Then the cursor is blinking. BEER Text PRI CE Guidance message 100 Current setting is displayed. 200 Guidance message ENTER DEPT# Guidance message/PLU code Inputted DEPT no. 01 If you want to set PLU delete. Please set 0. ENTER PLU TYPE Guidance message PLU Current setting is displayed. SUBDEPT Guidance message PLU Guidance message PLU . 0002 0002 PLU2 TEXT/PLU CODE ENTER [ 00 ] KEY RETURN TO 1'st STEP 0. 00 PLU1 SET UP TERMINATE (*) In case of text setting, you can use [X] or [.] key. If you push [X] key, the cursor moves to the left. And if you push [.] key, the cursor moves to the right. PROGRAMMING FOR (-). KEY ENTRY [(-)] ->[00] ->[ST] -> ->200 ->[ST] -> -> [00] ->[ST] -> -> [00] ->[ST] -> -> [00] ->[ST] -> -> 8 [ST] OPERATER 1234567890123456 NOTE ( - ) PROGRAMM I NG (-) PROGRAMMING ENTER [ 00 ] KEY ENTER TEXT Message of "ENTER TEXT" is displayed. (-) Current (-) text is displayed. Then the cursor is blinking. ENTER AMOUNT Message of "ENTER AMOUNT" is displayed. 0 200 S I GN Guidance message (-) (+) ENTRY FOR I TEM Guidance message ITEM ENABLE I TEM D I SABLE ENTRY FOR SBTL Guidance message SBTL D I SABLE SBTL ENABLE L I M I T D I G I TS Guidance message 8 Current setting is displayed. 8 ( - ) PROGRAMM I NG (-) PROGRAMMING ENTER [ 00 ] KEY PROGRAMMING FOR %. KEY ENTRY [ % ] ->[00] ->[ST] -> ->12.34 ->[ST] -> -> [00] ->[ST] -> -> [00] ->[ST] -> -> [00] ->[ST] -> -> 90.00 [ST] OPERATER 1234567890123456 NOTE % PROGRAMM I NG % PROGRAMMING ENTER [ 00 ] KEY ENTER TEXT Message of "ENTER TEXT" is displayed. % Current % text is displayed. Then the cursor is blinking. ENTER RATE Message of "ENTER RATE" is displayed. 0.00 12.34 S I GN Guidance message (-) (+) ENTRY FOR ITEM Guidance message I TEM ENABLE I TEM D I SABLE ENTRY FOR SBTL Guidance message SBTL D I SABLE SBTL ENABLE % HALO PROG Guidance message 100. 00 Current setting is displayed. 90. 00 % PROGRAMM I NG % PROGRAMMING ENTER [ 00 ] KEY XE-A203/A213 PROGRAM MODE 2 - 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

XE-A203/A213
PROGRAM MODE
2 – 18
<CANCEL OPERATION>
In this case, price(200) and text (COFFEE) are not written to the preset
memory.
<Programming for PLU.>
(
*
) In case of text setting, you can use [X] or [.] key.
If you push [X] key, the cursor moves to the left. And if you push [.]
key, the cursor moves to the right.
PROGRAMMING FOR (-).
PROGRAMMING FOR %.
KEY ENTRY
OPERATER
1234567890123456
NOTE
[PLU5]
PLU . 0005
0005
PLU1 TEXT / PLU CODE
ENTER [ 00 ] KEY
ENTER [00]-KEY TO CHANGE
TEXT
->[00]
ENTER
TEXT
Message of "ENTER TEXT" is
displayed.
PLU .
0005
->COFFEE
COFFEE _
->[ST]
PR I CE
Guidance message
->
100
->200
200
->[ST]
ENTER
DEPT#
PRICE IS DECIDED
->
01
->[CL]
01
->[CL]
0 . 00
PLU5 SET UP TERMINATE
KEY ENTRY
OPERATER
1234567890123456
NOTE
[PLU1]
PLU .
0001
0001
PLU1 TEXT / PLU CODE
ENTER [
00
] KEY
->[00]
ENTER
TEXT
Message of "ENTER TEXT" is
displayed.
P
LU
.
0001
Current PLU1 text is displayed.
Then the cursor is blinking. (
*
)
->066
066
Text code is inputted.
->[00]
BL
U
.
0001
If [00] key is entered and input-
ted text is addressed.
Then the cursor is blinking.
->EER
( is set space)
BEER
Text
->[ST]
PR
I
CE
Guidance message
->
100
Current setting is displayed.
->200
200
Guidance message
->[ST]
ENTER
DEPT#
Guidance message/PLU code
->01
01
Inputted DEPT no.
If you want to set PLU delete.
Please set 0.
->[ST]
ENTER
PLU
TYPE
Guidance message
->
PLU
Current setting is displayed.
-> [00]
SUBDEPT
Guidance message
-> [00]
PLU
Guidance message
->[ST]
PLU
. 0002
0002
PLU2 TEXT/PLU CODE
ENTER
[
00
] KEY
RETURN TO 1'st STEP
->[TL]
0. 00
PLU1 SET UP TERMINATE
KEY ENTRY
OPERATER
1234567890123456
NOTE
[(-)]
(
-
)
PR
OGR
A
MM
I N
G
(-) PROGRAMMING
ENTER
[
00
] KEY
->[00]
ENTER
TEXT
Message of "ENTER TEXT" is
displayed.
(
-
)
Current (
-
) text is displayed.
Then the cursor is blinking.
->[ST]
ENTER
AMOUNT
Message of "ENTER
AMOUNT" is displayed.
->
0
->200
200
->[ST]
S I GN
Guidance message
->
(
-
)
-> [00]
(
+
)
->[ST]
ENTRY
F
OR
I TE
M
Guidance message
->
ITE
M
ENABLE
-> [00]
I TEM
D
I
SABLE
->[ST]
ENTRY
F
OR
SBTL
Guidance message
->
SBTL
D I SABLE
-> [00]
SBTL
ENABLE
->[ST]
L I M I T
D I G I TS
Guidance message
->
8
Current setting is displayed.
-> 8
8
[ST]
(
-
)
PR
OGR
A
MM
I N
G
(-) PROGRAMMING
ENTER
[
00
] KEY
KEY ENTRY
OPERATER
1234567890123456
NOTE
[ % ]
%
PR
OGR
A
MM
I NG
% PROGRAMMING
ENTER [ 00 ] KEY
->[00]
ENTER
TEXT
Message of "ENTER TEXT" is
displayed.
%
Current % text is displayed.
Then the cursor is blinking.
->[ST]
ENTER
RATE
Message of "ENTER RATE" is
displayed.
->
0.00
->12.34
12.34
->[ST]
S I GN
Guidance message
->
(
-
)
-> [00]
(
+
)
->[ST]
ENTRY FOR
ITE
M
Guidance message
->
I
TE
M
ENABLE
-> [00]
I TEM
D I SABLE
->[ST]
ENTRY
F
O
R
SBTL
Guidance message
->
SBTL
D I SABLE
-> [00]
SBTL
ENABLE
->[ST]
%
HALO
PROG
Guidance message
->
100. 00
Current setting is displayed.
-> 90.00
90. 00
[ST]
%
PR
OGR
A
MM
I NG
% PROGRAMMING
ENTER [ 00 ] KEY