Sony FCBEX11DP User Manual (FCB-EX11D_Technical_Manual) - Page 12
Synchronization methods, NTSC=28.636363 MHz
View all Sony FCBEX11DP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Synchronization methods Internal and external synchronization are available; VISCA Commands allow you to switch between them. • Internal synchronization An internal vibrator inside the camera generates a synchronizing signal as a basic oscillator. NTSC=28.636363 MHz PAL=17.7344 MHz • External synchronization (V-Lock Synchronization 1)) When a TTL level V-Lock pulse is input, the camera synchronizes to the input signal (V-Lock synchronization). The frequency of the input signal synchronizes to within ±1Hz of the external synchronization. Also, 360 degree phase adjustment is possible due to the phase adjustment of the V-Lock signal. Because V-Lock synchronization is a simple synchronization method, color signals like a VBS "Genlock" signal cannot be synchronized. 1) In V-Lock synchronization, the camera makes a V-Lock pulse (VL-PULSE) which synchronizes to the commercial power supply and uses it as the external synchronization input signal of the camera, using the fact that the V cycle (59.97 Hz vertical synchronization signal) and the frequency of the commercial power supply (60 Hz). The synchronous signal of the camera will automatically sychronizes to the VL-PULSE in the camera. Basic Functions 12