Thermador PH36GS Design Guide - Ventilation - Page 10
Remote Mounted To Roof Or External Wall, Inline Mounted Between Kitchen And External Wall
View all Thermador PH36GS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
VENTILATION BLOWER options AND PRESSURE CURVES REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL) VTR630D - 600 CFM VTR1030D - 1000 CFM VTR1330E - 1300 CFM INLINE (MOUNTED BETWEEN KITCHEN AND EXTERNAL WALL) VTI610D - 600 CFM VTI1010D - 1000 CFM NOTE: All measurements are made with 3 ft. straight duct, 90° bend followed by 1 ft. straight duct. These are NOT free blowing measurements. 1.800.735.4328 | THERMADOR.COM 137
1.800.735.4328
|
THERMADOR.COM
VENTILATION
137
REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL)
VTR630D – 600 CFM
VTR1030D – 1000 CFM
VTR1330E – 1300 CFM
INLINE (MOUNTED BETWEEN KITCHEN AND EXTERNAL WALL)
VTI610D – 600 CFM
VTI1010D – 1000 CFM
NOTE:
All measurements are
made with 3 ft. straight duct,
90° bend followed by 1 ft.
straight duct. These are NOT
free blowing measurements.
BLOWER OPTIONS AND PRESSURE CURVES