Toshiba R600-S4201 Maintenance Manual - Page 173
Target Low, Rpm Result Low: XXXX Rpm OK, Target High: 3800 Rpm Result High: XXXX Rpm OK
UPC - 883974166565
View all Toshiba R600-S4201 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 173 highlights
3.20 ONLY ONE TEST Subtest 8 Docker Dock/Undock 3 Tests and Diagnostics Rev B This subtest is executed with an Slim Port Replicator II. installed. Press Enter while pushing the eject button of the Slim Port Replicator II. the following message appears. Pushing Eject-SW, and press [Enter] Key Press Enter without pushing the eject button of the Slim Port Replicator II. after the following message appears. Release Eject-SW, and press [Enter] Key If the test ends successfully, the display returns to the ONLY ONE TEST menu. When the display returns to the ONLY ONE TEST menu, remove the Express Port Replicator from the computer. Subtest 09 Fan control This subtest checks if FAN works properly. The following message appears in the display in order. ! Start low-speed rotation..........Waits 8 seconds ! Start reading of rotation............Waits 3 seconds ! Start Hight-speed rotation........Waits 8 seconds ! Start reading of rotation............Waits 3 seconds FAN Low-speed----> Target Low: 3900 Rpm Result Low: XXXX Rpm OK! FAN High-speed---> Target High: 3800 Rpm Result High: XXXX Rpm OK! OK message appears in the display if the test ends without a defective. NG message appears in the display if a defective is found during the test. PORTEGE R600 Maintenance Manual (960-709) [CONFIDENTIAL] 3-49