Uniden BC92XLT English Owners Manual - Page 57

Sensitivity S+N/N = 20 dB

Page 57 highlights

Sensitivity (S+N)/N = 20 dB 25.005 MHz (AM 0.5 µV 40.840 MHz (FM 0.3 µV 49.900 MHz (FM 0.3 µV 118.800 MHz (AM 0.5 µV 127.175 MHz (AM 0.5 µV 135.500 MHz (AM 0.5 µV 138.150 MHz (FM 0.3 µV 162.400 MHz (FM 0.3 µV 173.225 MHz (FM 0.3 µV 406.875 MHz (FM 0.3 µV 453.250 MHz (FM 0.3 µV 511.9125 MHz (FM 0.3 µV 806.000 MHz (FM 0.4 µV 857.200 MHz (FM 0.4 µV 954.9125 MHz (FM 0.4 µV Operating Temperature: Normal 20°C to +60°C Close Call 10°C to +50°C Scan Rate 50 channels per second (max) Search Rate Normal 60 steps per second (max) Hyper 180 steps per second (max) Priority Sampling 2 seconds Scan Delay 2 seconds IF Rejection (at 162.4 MHz 100 dB Specifications 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

57
Specifications
Sensitivity (S+N)/N = 20 dB
25.005 MHz (AM)
........................................
0.5 μV
40.840 MHz (FM)
........................................
0.3 μV
49.900 MHz (FM)
........................................
0.3 μV
118.800 MHz (AM)
........................................
0.5 μV
127.175 MHz (AM)
........................................
0.5 μV
135.500 MHz (AM)
.......................................
0.5 μV
138.150 MHz (FM)
........................................
0.3 μV
162.400 MHz (FM)
.......................................
0.3 μV
173.225 MHz (FM)
.......................................
0.3 μV
406.875 MHz (FM)
........................................
0.3 μV
453.250 MHz (FM)
.......................................
0.3 μV
511.9125 MHz (FM)
.....................................
0.3 μV
806.000 MHz (FM)
........................................
0.4 μV
857.200 MHz (FM)
........................................
0.4 μV
954.9125 MHz (FM)
.....................................
0.4 μV
Operating Temperature:
Normal
...........................................
–20°C to +60°C
Close Call
......................................
–10°C to +50°C
Scan Rate:
...............
50 channels per second (max)
Search Rate
Normal
..........................
60 steps per second (max)
Hyper
..........................
180 steps per second (max)
Priority Sampling
.....................................
2 seconds
Scan Delay:
............................................
2 seconds
IF Rejection (at 162.4 MHz)
.........................
100 dB