Viking VWH2448SS Installation Instructions - Page 20

Installation, Duct Cover Option

Page 20 highlights

6 5/16" nut driver CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary. 7 BARE OR GREEN WHITE WHITE GREEN BLACK BLACK 5/16" nut driver CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting screws, if necessary. 8 1 1 2 Connect black to black, white to white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit. 9 1 Replace electrical box cover. Make connection to breaker box. 10 1 3 2 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. 2 3 Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. 38 11 1 2 3 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Duct Cover Option (VWH 10"H. Wall Hoods w/Standard Ventilator) 1 2 2 Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. Installation (VWH 10"H. Wall Hoods w/Recirculating Kit) 1 2 Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood upside down on recirculating unit. 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

38
CAUTION:
If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing. Use additional mounting
screws, if necessary.
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE:
Housing wiring must be properly installed for
wiring to be correct when wiring unit.
5/16”
nut driver
BLACK
BLACK
WHITE
WHITE
GREEN
BARE OR GREEN
7
39
Replace electrical box cover. Make connection to
breaker box.
1
2
3
9
1
1
2
8
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
2
1
3
10
1
2
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
Installation
(VWH 10”H. Wall Hoods w/Recirculating Kit)
1
2
2
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Duct Cover Option
(VWH 10”H. Wall Hoods w/Standard Ventilator)
1
2
3
11
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
CAUTION:
Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.
6
5/16”
nut driver