PDP DISPLAY NOTHINGAnalog HD1 on PIP mode without Pb signal
View all Vizio VP50HDTV10A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
PDP DISPLAY NOTHING(Analog HD1 on PIP mode without Pb signal) BLOCK 1 No Is picture on screen? Check component 1 No (Pb signal) ÎC255 Is there sync? Trace componect 1 from Input To U10 circuit Check R200,R198 Yes Use GProbe connect No from main to PC. Does scaler detect the signal? U10 fail PDP DISPLAY NOTHING(Analog HD1 on PIP mode without Pr signal) BLOCK 1 No Is picture on screen? Check component 1 No (Pr signal) ÎC255 Is there sync? Trace componect 1 from Input To U10 circuit Check R205,R204 Yes Use GProbe connect No from main to PC. Does scaler detect the signal? U10 fail PDP DISPLAY NOTHING(Analog HD2 without Y signal) BLOCK 1 Is picture on screen? No Check component 2 (Y signal) ÎC258,R195 Is there sync? Yes Check U23 No outnputÎpin 31 No InputÎ pin 13 Input clamp voltageÎpin 3(+5V) Output clamp voltageÎpin 32(+5V) VCC3Îpin 22,23(+5V) Input_switch_selectÎhigh(+5V) U23 fail Use GProbe connect No from main to PC. Does scaler detect the signal? U13 fail Yes Check before U23's circuit No 1.C263,C265(AC coupled) 2.R209 Input source fail 3.R216(75ohm) 3 CONFIDENTIAL - DO NOT COPY Page 9-8 File No. SG-0219