CHANGING TO A 30- OR 60-MINUTE TIMING CAM WARNING Electrical Shock Hazard Disconnect power before making cam changes. Failure to follow these instructions can result in death or electrical shock. You can install the 30-minute or 60-minute timing cam (shipped with dryer) as follows: 1. Unplug dryer or disconnect power. 2. Unlock meter case. 3. Turn the timing cam by hand until the V-shaped notch lines up below the ratchet tooth. A B C D A. Ratchet tooth B. Timing cam C. Drive lug D. V-shaped notch 4. Insert a narrow, flat-blade screwdriver under the timing cam near the clock shaft. Gently lift cam straight up and off shaft making sure that the V-shaped notch clears the ratchet tooth. 5. Place new cam (hub side down) over clock shaft. Line up flat side of shaft with flat side of cam hole. Check that drive lug is in place. 6. Turn cam until V-shaped notch lines up with ratchet tooth. 7. Press cam down in place on motor shaft. Make sure that V-shaped notch clears the ratchet tooth. 8. Close and lock the meter case. 16