Whirlpool GLS3064RS Installation Instructions - Page 3

Mobile Home - Additional Installation Requirements, Product Dimensions, Gas and Electric Connection - 30

Page 3 highlights

■ Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances. ■ Grounded electrical supply is required. See "Electrical Requirements" section. ■ Proper gas supply connection must be available. See "Gas Supply Requirements" section. ■ The gas and electric supply should be located as shown in "Gas and Electric Connection Locations" in the "Location Requirements" section so that they are accessible without requiring removal of the cooktop. IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. Mobile Home - Additional Installation Requirements The installation of this cooktop must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes. In Canada, the installation of this cooktop must conform with the current standards CAN/CSA-A240-latest edition, or with local codes. Product Dimensions 30" (76.2 cm) Model Gas and Electric Connection Locations A C B CL D A. Gas pressure regulator (supplied) - arrow pointed toward cooktop B. 3 prong grounding type outlet with correct polarity C. 18" (45.7 cm) minimum D. Gas shutoff valve Installation Clearances IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. D A B C F C B A. 30" (76.2 cm) B. 20¹⁄₈" (51.1 cm) C. 2 7.2 cm) 36" (91.4 cm) Model A C B A. 36" (91.4 cm) B. 20¹⁄₈" (51.1 cm) C. 2 7.2 cm) J A I E G H A. 18" (45.7 cm) minimum clearance upper cabinet to countertop B. Cabinet C. 30" (76.2 cm) on 30" (76.2 cm) models 36" (91.4 cm) on 36" (91.4 cm) models D. 13" (33 cm) maximum recommended upper cabinet depth E. 6" (15.2 cm) minimum side wall clearance F. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is covered by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper) G. 2 5.9 cm) minimum distance to rear combustible surface H. 3 8.1 cm) minimum distance to front countertop edge I. Cutout width - 29³⁄₈" (74.6 cm) on 30" models; 35³⁄₈" (89.9 cm) on 36" models J. Cutout depth - 19¹⁄₂" (49.5 cm) NOTE: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the burner box. To avoid this modification, use a base cabinet with sidewalls wider than the cutout. If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may need to be shortened to avoid interfering with the regulator. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

3
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
Grounded electrical supply is required. See “Electrical
Requirements” section.
Proper gas supply connection must be available. See “Gas
Supply Requirements” section.
The gas and electric supply should be located as shown in
“Gas and Electric Connection Locations” in the “Location
Requirements” section so that they are accessible without
requiring removal of the cooktop.
IMPORTANT:
To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage.
Mobile Home - Additional Installation Requirements
The installation of this cooktop must conform to the
Manufactured Home Construction and Safety Standard, Title 24
CFR, Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this cooktop must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Product Dimensions
30" (76.2 cm) Model
36" (91.4 cm) Model
Gas and Electric Connection Locations
Installation Clearances
IMPORTANT:
If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
NOTE:
After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the burner box. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened
to avoid interfering with the regulator.
A. 30" (76.2 cm)
B. 20
¹⁄₈
" (51.1 cm)
C. 2
²⁷⁄₃₂
" (7.2 cm)
A. 36" (91.4 cm)
B. 20
¹⁄₈
" (51.1 cm)
C. 2
²⁷⁄₃₂
" (7.2 cm)
A
C
B
A
B
C
A. Gas pressure regulator (supplied) - arrow pointed
toward cooktop
B. 3 prong grounding type outlet with correct polarity
C. 18" (45.7 cm) minimum
D. Gas shutoff valve
A. 18
"
(45.7 cm) minimum clearance upper cabinet to countertop
B. Cabinet
C. 30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
D. 13" (33 cm) maximum recommended upper cabinet depth
E. 6
"
(15.2 cm) minimum side wall clearance
F. 30
"
(76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered wood or metal cabinet
(24
"
[61 cm] minimum clearance if bottom of wood or metal
cabinet is covered by not less than
¹⁄₄
"
[0.6 cm] flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015
"
[0.04 cm] stainless steel, or 0.024
"
[0.06 cm] aluminum
or 0.020
"
[0.05 cm] copper)
G. 2
⁵⁄₁₆
" (5.9 cm) minimum distance to rear combustible surface
H. 3
³⁄₁₆
" (8.1 cm) minimum distance to front countertop edge
I. Cutout width - 29
³⁄₈
" (74.6 cm) on 30" models; 35
³⁄₈
" (89.9 cm)
on 36" models
J. Cutout depth - 19
¹⁄₂
" (49.5 cm)
C
L
C
A
B
D
B
A
D
E
C
F
G
H
I
J