Whirlpool GXU7130DXB Dimension Guide - Page 2
x 10 8.3 cm x 25.4 cm Vent System, Vent Piece, Example vent system, Maximum Recommended Length, 35
View all Whirlpool GXU7130DXB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System Vent Piece 3¹⁄₄" x 10" (8.3 cm x 5.0 ft (1.5 m) 25.4 cm) 90° elbow 3¹⁄₄" x 10" (8.3 cm x 12.0 ft (3.7 m) 25.4 cm) flat elbow 3¹⁄₄" x 10" (8.3 cm x 0.0 ft (0.0 m) 25.4 cm) wall cap Example vent system 3¹⁄₄" x 10" (8.3 x 25.4 cm) elbow 6 ft (1.8 m) Wall cap 2 ft (0.6 m) Maximum Recommended Length = 35 ft (10.7 m) 1 - 90° elbow 8 ft (2.4 m) straight 1 - wall cap = 5.0 ft (1.5 m) = 8.0 ft (2.4 m) = 0.0 ft (0.0 m) Length of 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) system = 13.0 ft (3.9 m) INSTALLATION CLEARANCES C B D A E A. 18" (45.7 cm) min. clearance - upper cabinet to countertop B. 24" (61.0 cm) min. for electric cooking surfaces 27" (68.6 cm) min. for gas cooking surfaces 30" (76.2 cm) suggested max. - bottom of range hood to cooking surface C. 30" (76.2 cm) min. cabinet opening width D. 13" (33.0 cm) cabinet depth E. 36" (91.4 cm) base cabinet height Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Page 2 of 2 Ref. W10320576A 10/20/10