4. Drill two ¹⁄₈" (3 mm) holes that correspond to the bracket holes of the determined mounting method. See below. Floor Mounting Wall Mounting A B A B A. #12 x 1⁵⁄₈" screws B. Anti-tip bracket A. #12 x 1⁵⁄₈" screws B. Anti-tip bracket 5. Using the Phillips screwdriver, mount anti-tip bracket to the wall or floor with the two #12 x 1⁵⁄₈" screws provided. Power Supply Cord Electrical Connection - U.S.A. Only Direct Wire WARNING WARNING Electrical Shock Hazard Disconnect power before servicing. Use a new 40 amp power supply cord. Plug into a grounded outlet. Failure to follow these instructions can result in death, fire, or electrical shock. Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Electrically ground range. Failure to follow these instructions can result in death, fire, or electrical shock. 1. Disconnect power. 2. Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range. Pull cover down and toward you to remove cover. 3. Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block. 7