Whirlpool SCS3617RQ Installation Instructions - Page 3

Mobile Home - Additional Installation Requirements, Product Dimensions, Installation Clearances

Page 3 highlights

s The gas and electric supply should be located as shown in "Installation Clearances" section so that they are accessible without requiring removal of the cooktop. s Provide cutout in right rear corner of cutout enclosure as shown to provide clearance for gas inlet, power supply cord, and to allow the rating label to be visible. IMPORTANT: To avoid damage, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. Mobile Home - Additional Installation Requirements The installation of this cooktop must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes. In Canada, the installation of this cooktop must conform with the current standards CAN/CSA-A240-latest edition, or with local codes. Product Dimensions Metal Cooktops B A C A. 21¹⁄₄" (53.4 cm) B. 31 79.8 cm) on 30" (76.2 cm) models, 37 95.4 cm) on 36" (91.4 cm) models C. 2⁷⁄₈" (7.3 cm) Straight-edge glass cooktops B A C A. 20 51.5 cm) B. 30 76.8 cm) on 30" (76.2 cm) models, 36 92.5 cm) on 36" (91.4 cm) models C. 2⁷⁄₈" (7.3 cm) Curved-edge glass cooktops B Installation Clearances A D C B M KEF G H L J I A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models B. Combustible area above countertop (shown by dashed box above) C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of unprotected wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is protected by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper) D. 13" (33 cm) maximum upper cabinet depth E. 2¹⁄₈" (5.4 cm) F. 19" (48.3 cm) G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop H. Grounded outlet - Locate within 24" (61 cm) of right rear corner of cutout I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models J. 8³⁄₈" (21.3 cm) minimum distance to nearest left and right side combustible surface K. 2⁷⁄₈" (7.3 cm) minimum distance to rear combustible surface L. Gas line opening - Wall: anywhere 5" (12.7 cm) below underside of countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended M. 24" (61 cm) minimum countertop depth is required NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the burner box. To avoid this modification, use a base cabinet with sidewalls wider than the cutout. If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may need to be shortened to avoid interfering with the regulator. If installing a hood above the range, follow the hood instructions for dimensional clearances above the cooktop surface. A C A. 21¹⁄₈" (53.7 cm) B. 30 77.0 cm) on 30" (76.2 cm) models, 36 92.3 cm) on 36" (91.4 cm) models C. 2⁷⁄₈" (7.3 cm) 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

3
The gas and electric supply should be located as shown in
Installation Clearances
section so that they are accessible
without requiring removal of the cooktop.
Provide cutout in right rear corner of cutout enclosure as
shown to provide clearance for gas inlet, power supply cord,
and to allow the rating label to be visible.
IMPORTANT:
To avoid damage, check with your builder or
cabinet supplier to make sure that the materials used will not
discolor, delaminate or sustain other damage.
Mobile Home - Additional Installation Requirements
The installation of this cooktop must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this cooktop must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Product Dimensions
Metal Cooktops
Straight-edge glass cooktops
Curved-edge glass cooktops
Installation Clearances
NOTES:
After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the burner box. To avoid this modification, use a base cabinet with
sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened
to avoid interfering with the regulator.
If installing a hood above the range, follow the hood instructions
for dimensional clearances above the cooktop surface.
A. 21
¹⁄₄
" (53.4 cm)
B. 31
⁷⁄₁₆
" (79.8 cm) on 30" (76.2 cm) models,
37
⁹⁄₁₆
" (95.4 cm) on 36" (91.4 cm) models
C. 2
⁷⁄₈
" (7.3 cm)
A. 20
⁵⁄₁₆
" (51.5 cm)
B. 30
³⁄₁₆
" (76.8 cm) on 30" (76.2 cm) models,
36
⁷⁄₁₆
" (92.5 cm) on 36" (91.4 cm) models
C. 2
⁷⁄₈
" (7.3 cm)
A. 21
¹⁄₈
" (53.7 cm)
B. 30
⁵⁄₁₆
" (77.0 cm) on 30" (76.2 cm) models,
36
⁵⁄₁₆
" (92.3 cm) on 36" (91.4 cm) models
C. 2
⁷⁄₈
" (7.3 cm)
A
B
C
C
A
B
A
B
C
A. 30
"
(76.2 cm) on 30
"
models; 36
"
(91.4 cm) on 36
"
models
B. Combustible area above countertop (shown by dashed box
above)
C. 30
"
(76.2 cm) minimum clearance between top of cooktop
platform and bottom of unprotected wood or metal cabinet
(24
"
[61 cm] minimum clearance if bottom of wood or metal
cabinet is protected by not less than
¹⁄₄
"
[0.6 cm] flame
retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015
"
[0.04 cm] stainless steel, or
0.024
"
[0.06 cm] aluminum or 0.020
"
[0.05 cm] copper)
D. 13
"
(33 cm) maximum upper cabinet depth
E. 2
¹⁄₈
"
(5.4 cm)
F. 19
"
(48.3 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to
countertop within minimum horizontal clearances to cooktop
H. Grounded outlet - Locate within 24" (61 cm) of right rear
corner of cutout
I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models
J. 8
³⁄₈
" (21.3 cm) minimum distance to nearest left and right side
combustible surface
K. 2
⁷⁄₈
" (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: anywhere within
6" (15.2 cm) of rear wall is recommended
M. 24" (61 cm) minimum countertop depth is required
B
D
A
C
E
F
H
I
J
G
K
L
M