Page 13 highlights
Non-Vented (recirculating) Installation Filters The charcoal filter is not washable. It should last up to 6 months with normal use. Replace with Charcoal Filter Kit Number W10272068. To replace charcoal filter: 1. Cover the grille that covers the blower motor with the charcoal filter so that the slots on the filter correspond to the pins on the sides of the motor grille. Replacing a Halogen Lamp Turn off the range hood and allow the halogen lamp to cool. To avoid damage or decreasing the life of the new bulb, do not touch bulb with bare fingers. Replace bulb, using tissue or wearing cotton gloves to handle bulb. If new lamps do not operate, make sure the lamps are inserted correctly before calling service. 1. Disconnect power. 2. Push up on the lens and turn it counterclockwise. AB C A. Charcoal filter B. Pins C. Blower motor 2. Turn the charcoal filter clockwise to lock it. 3. Repeat steps 1-2 on the other filter. 3. Remove the bulb and replace it with a 120-volt, 50-watt maximum halogen bulb with a GU10 base. Turn it clockwise to lock it into place. 4. Repeat steps 2-3 for the other bulb if needed. 5. Reconnect power. 13