Whirlpool UXT4230ADS Use & Care Guide - Page 8

Drill Electrical Opening, Prepare Range Hood Vents and, Mounting Tabs, Attach Vent Damper or

Page 8 highlights

7. Drill Electrical Opening 9. Attach Vent Damper or Transition 3¹⁄₄" x 10" (8.3 x 25.4 cm) Rectangular Vent Damper Using a 1¹⁄₄" (3 cm) drill bit, drill the hole in the dot marked previously at the electrical strain relief. OPTIONAL: Using a ¹⁄₈" (3 mm) drill bit, drill pilot holes for the dots marked previously at each mounting tab at an approximate 45° angle in an upward direction. 8. Prepare Range Hood Vents and Mounting Tabs x2 F ■ Using (2) short Phillips head screws, install the 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular damper over the top or rear vent knockout removed in Step 8. NOTE: If the wall cap used has a damper and it interferes with the rectangular damper, remove the rectangular damper flap. 7" (17.8 cm) Round Vent Mounting Plate E D C B A A C B ■ Install Strain Relief Install a UL Listed/CSA Approved ¹⁄₂" (13 mm) strain relief (A). ■ Mounting Tabs Start a #8-18 x 4.2 x 16 mm) truss-head screw into the mounting tab (F) on each side of the range hood as shown in the inset. Insert the screws approximately 2 turns into the mounting tab holes. ■ Non-vent (Recirculating) Installations Remove the (2) T10® Torx® screws and remove the top, front rectangular vent cover (E). Go to Step 12. ■ 3¹⁄₄" x 10" (8.3 x 25.4 cm) Rectangular Vent Installations For top vent installations, remove the top, rectangular vent knockout (C). OR For wall vent installations, remove the rear rectangular vent knockout (B). ■ 7" (17.8 cm) Round Vent Installations Remove both top knockouts (C and D). ■ Using (2) short Phillips head screws, install the 7" (17.8 cm) round vent mounting plate over the vent knockouts removed in Step 8. Position the wide flange (C) to the front. NOTE: An optional 7" (17.8 cm) round damper (A), Part Number W10355451, and a 7" (17.8 cm) round vent mounting plate (B), Part Number W10388168, are available as accessories. For information on ordering, see the "Assistance or Service" section. ■ If installing the optional round damper, position it over the round vent mounting plate. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

8
7.
Drill Electrical Opening
Using a 1
¹⁄₄
" (3 cm) drill bit, drill the hole in the dot marked
previously at the electrical strain relief.
OPTIONAL:
Using a
¹⁄₈
" (3 mm) drill bit, drill pilot holes for the
dots marked previously at each mounting tab at an approximate
45° angle in an upward direction.
8.
Prepare Range Hood Vents and
Mounting Tabs
Install Strain Relief
Install a UL Listed/CSA Approved
¹⁄₂
" (13 mm) strain relief (A).
Mounting Tabs
Start a #8-18 x
⁵⁄₈
" (4.2 x 16 mm) truss-head screw into the
mounting tab (F) on each side of the range hood as shown in
the inset. Insert the screws approximately 2 turns into the
mounting tab holes.
Non-vent (Recirculating) Installations
Remove the (2) T10
®
Torx
®
screws and remove the top, front
rectangular vent cover (E). Go to Step 12.
3
¹⁄₄
" x 10" (8.3 x 25.4 cm) Rectangular Vent Installations
For top vent installations, remove the top, rectangular vent
knockout (C).
OR
For wall vent installations, remove the rear rectangular vent
knockout (B).
7" (17.8 cm) Round Vent Installations
Remove both top knockouts (C and D).
9.
Attach Vent Damper or Transition
3
¹⁄₄
" x 10" (8.3 x 25.4 cm) Rectangular Vent Damper
Using (2) short Phillips head screws, install the 3
¹⁄₄
" x 10" (8.3
x 25.4 cm) rectangular damper over the top or rear vent
knockout removed in Step 8.
NOTE:
If the wall cap used has a damper and it interferes
with the rectangular damper, remove the rectangular damper
flap.
7" (17.8 cm) Round Vent Mounting Plate
Using (2) short Phillips head screws, install the 7" (17.8 cm)
round vent mounting plate over the vent knockouts removed
in Step 8. Position the wide flange (C) to the front.
NOTE:
An optional 7" (17.8 cm) round damper (A), Part
Number W10355451, and a 7” (17.8 cm) round vent mounting
plate (B), Part Number W10388168, are available as
accessories. For information on ordering, see the “Assistance
or Service” section.
If installing the optional round damper, position it over the
round vent mounting plate.
A
B
C
D
E
x2
F
A
B
C