Whirlpool WED5800BC Installation Guide - Page 10

wire Direct Wire Connection, wire Direct Wire Connection

Page 10 highlights

4-wire Direct Wire Connection IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections. 1. Prepare your 4-wire cable for direct connection (251"mm) 4. Connect ground wire (127 5" mm) Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 11/2" (38 mm) from remaining 3 wires. Strip insulation back 1" (25 mm). Shape ends of wires into hooks. 2. Prepare to connect neutral ground wire and neutral wire AF Connect ground wire (green or bare) (F) of direct wire cable to external ground conductor screw (A). Tighten screw. 5. Connect remaining wires E B A Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A). 3. Connect neutral ground wire and neutral wire B C E Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements. 3-wire Direct Wire Connection IMPORTANT: Use where local codes permit connecting cabinet-ground conductor to neutral wire. 1. Prepare your 3-wire cable for direct connection (251"mm) (893m½m" ) Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw. 10 Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. Strip 31/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

10
4-wire Direct Wire Connection
IMPORTANT:
A 4-wire connection is required for mobile homes
and where local codes do not permit 3-wire connections.
2.
Prepare to connect neutral
ground wire and neutral wire
E
A
B
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer
may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving
bare ground wire at 5" (127 mm). Cut 1
1
/
2
" (38 mm) from
remaining 3 wires. Strip insulation back 1" (25 mm). Shape ends
of wires into hooks.
1"
(25 mm)
5"
(127 mm)
1.
Prepare your 4-wire cable for
direct connection
3-wire Direct Wire Connection
IMPORTANT:
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
4.
Connect ground wire
A
F
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
Venting Requirements.
5.
Connect remaining wires
B
E
C
3.
Connect neutral ground wire
and neutral wire
Connect neutral ground wire (E) and place
hooked end (hook facing right) of neutral wire (white or center
wire) (C) of direct wire cable under center screw of terminal
block (B). Squeeze hooked ends together and tighten screw.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 3
1
/
2
" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
1"
(25 mm)
3½"
(89 mm)
1.
Prepare your 3-wire cable for
direct connection