Whirlpool WED6400SB Installation Instructions - Page 3
Location Requirements - dryer
UPC - 883049025094
View all Whirlpool WED6400SB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Location Requirements Dryer Dimensions 431/2" (1105 mm) 291/4" (743 mm) 29" (737 mm) 221/4" (565 mm) You will need ■ A location that allows proper exhaust installation. See "Venting Requirements." ■ A separate 30-amp circuit. ■ If using a power supply cord, a grounded electrical outlet within 2 ft (610 mm) of either side of dryer. See "Electrical Requirements." ■ A sturdy floor to support total dryer weight of 200 lbs. (90.7 kg). Also consider combined weight of a companion appliance. ■ A level floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level. ■ For a garage installation, place dryer at least 18" (457 mm) above floor. If using a pedestal, you will need 18" (457 mm) to bottom of dryer. ■ Steam models only: Cold water faucets located within 4 ft. (1.2 m) of dryer, and water pressure of 20-100 psi (137.9-689.6 kPa). Cold water supply may come from washer using "Y" connector provided. Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer may not shut off at the end of an automatic sensor cycle, possibly resulting in longer drying times. Do not install or store dryer where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. Installation clearances Location must be large enough to allow dryer door to open fully. NOTE: Most installations require minimum 5" (127 mm) clearance for exhaust vent with elbow. See "Venting Requirements." Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. Dryer has been tested for spacing of 0" (0 mm) clearance on sides and rear. Consider recommended spacing for following reasons: ■ Consider additional spacing for ease of installation and service. ■ May need additional clearance for wall, door, and floor moldings. ■ Consider additional spacing on all sides of dryer to reduce noise transfer. ■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Equivalent ventilation openings in louvered doors are acceptable. ■ Consider spacing for companion appliance. ■ Additional space required for rear exhaust of dryer to right or left. 18"* (457 mm) 1" (25 mm) 29" (737 mm) Recessed area 14" máx.* (356 mm) 48" 2* (310 cm2) 3"* (76 mm) 24" 2* (155 cm2) 3"* (76 mm) 1" (25 mm) 291/4" (743 mm) 5" (127 mm) Side view- closet or confined area Closet door with vents *Required spacing Mobile home - Additional installation requirements Dryer is suitable for mobile home installations. Installation must conform to Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/ CSA-Z240 MH. Mobile home installations require: ■ Metal exhaust system hardware, available for purchase from your dealer. ■ Special provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening. 3