Whirlpool WED95HEXL Dimension Guide - Page 1
Whirlpool WED95HEXL Manual
UPC - 883049217260
View all Whirlpool WED95HEXL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Electric Dryer Installation Instructions PRODUCT MODEL NUMBERS WED94HEX, WED95HEX, WED97HEX, WEDXXHEX Electrical: This dryer requires a 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result. Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. Hood styles: A & B are recommended. A B C A. Louvered hood B. Box hood C. Angled hood (acceptable) The Vent system chart provides venting requirements that will help achieve best drying performance. NOTE: Side and bottom exhaust installation have a 90° turn inside the dryer. To determine maximum exhaust length, add a 90° turn to the total number of elbows when referemcing the chart. Number of 90° elbows Vent system chart Type of vent Box/louvered hoods Angled hoods 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m) 2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m) 3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need. OVERALL DIMENSIONS Dryer dimensions Front view: 27" (686 mm) Side view: 507/8" (1292 mm) 305/8" (728 mm) 381/8" (968 mm) 3/4"* (18 mm) Back view: 61/2" (165 mm) Left or right side exhaust 3/4"* (18 mm) 297/8"* (759 mm) 31/2"* (89 mm) NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See "Venting Requirements." 3/4"* (18 mm) 143/8" (365 mm) 61/8"* (156 mm) * Approximate measurement Closet installation (dryer only): 5" (127 mm) 18" min. (457 mm) 3" (76 mm) 48 in.2 min. (310 cm2) 1" (25 mm) 1" (25 mm) 24 in.2 min. (155 cm2) 3" (76 mm) For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10057363B 12/2010