Whirlpool WFE775H0HW Installation Instructions - Page 9
Electrical Connection - U.S.A. Only
View all Whirlpool WFE775H0HW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
Power Supply Cord Electrical Connection - U.S.A. Only Direct Wire WARNING 1. Disconnect power. 2. Remove the terminal block cover screws located on the back of the range. Pull the cover down and toward you to remove cover from range. Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Electrically ground range. Failure to follow these instructions can result in death, fire, or electrical shock. OR Remove the top 10-32 hex nut from each of the 3 terminal blocks and set aside. A B 4. Add strain relief. Style 1: Power supply cord strain relief ■■ Remove the knockout for the power supply cord. ■■ Assemble a UL Listed strain relief in the opening. C A. Two mounting tabs each side B. Terminal block cover C. Hex-head screws 3. Depending on your model, remove the plastic tag holding three 10-32 hex nuts from the middle post of the terminal block. PLARCEEMNOUVETSPOLANSTTOICTHTAEGBALONCDKS A A. UL Listed strain relief ■■ Tighten strain relief screw against the power supply cord. 9