Whirlpool WFW9640XW Dimension Guide - Page 1
Whirlpool WFW9640XW Manual
View all Whirlpool WFW9640XW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Front-Loading Automatic Washer PRODUCT MODEL NUMBERS WFW9640X Electrical: A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided. Drain System Options Standpipe drain system - wall or floor (views A & B) The standpipe drain requires a minimum diameter standpipe of 2" (50 mm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. The top of the standpipe must be at least 30" (762 mm) high and no higher than 96" (2.4 m) from the bottom of the washer. Washer dimensions OVERALL DIMENSIONS Custom undercounter installation-washer only 521/2" (1335 mm) 27" (686 mm) 381/4" (970 mm) 39" min. (990 mm) 1" 27" 1" (25 mm) (686 mm) (25 mm) 321/2" (820 mm) 30" min. (762 mm) For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable. 34" min. 48 in.2 * (864 mm) (310 cm2) 3" (76 mm) 18" min (457 mm) A B Laundry tub drain system (view C) The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 30" (762 mm) above the floor. Floor drain system (view D) The floor drain system requires a siphon break that may be purchased separately. See "Tools and Parts." The siphon break must be a minimum of 28" (710 mm) from the bottom of the washer. Additional hoses might be needed. 24 in.2 * (155 cm2) 1" 311/2" 4" (25 mm) (800 mm) (102 mm) 3" (76 mm) 1" 27" 1" 1" 31½" 4" (25 mm) (686 mm) (25 mm) (25 mm) (800 mm) (102 mm) A. Side view - closet or confined area B. Closet door with vents A. Recessed area B. Side view - closet or confined area For cabinet installation, with a door, the minimum ventilation openings in the top are required. 30" min. (762 mm) 28" min. (710 mm) C D 48 in.2 * (310 cm2) 3"* (76 mm) 24 in.2 * (155 cm2) 3"* (76 mm) 1"* (25 mm) 6"* (152 mm) 7" 7" (178 mm) (178 mm) 9" (229 mm) 4" (102 mm) 311/2" 1" 27" 1" (800 mm) (25 mm) (686 mm) (25 mm) 5½"** (140 mm) 76" (1930 mm) * Required spacing ** For venting out the side, 1" (25 mm) spacing is allowed. 1" (25 mm) 27" (686 mm) 1" (25 mm) Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. 461970256991 03/2011