- Whirlpool WGD49STBW | Dimension Guide - Page 1
Dryer PRODUCT MODEL NUMBERS WGD49STB Side View 223/4" (578 mm) 273/4" (705 mm) 133/4" (349 mm) 273/4" (705 mm) 1/2" (13 mm) NOTE: Leveling legs should be 1/2" (13 mm) (to match height of 3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height of 3.8 cu. ft. capacity washer). Installation - Whirlpool WGD49STBW | Dimension Guide - Page 2
and servicing. ■■ Additional clearances might be required for wall, door, and floor moldings. ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. ■■ For closet installation, with a door, minimum ventilation openings in the top and bottom - Whirlpool WGD49STBW | Dimension Guide - Page 3
larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15
Gas Dryer
PRODUCT MODEL NUMBERS
W10646607A
12/2014
WGD49STB
29" Wide Models Dryer Dimensions
Front View
NOTE:
Leveling legs should be 1/2" (13 mm) (to match height of
3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height of
3.8 cu. ft. capacity washer).
29"
(737 mm)
43
3
/
8
"
(1102 mm)
1
/
2
"
(13 mm)
A
B
22
3
/
4
"
(578 mm)
27
3
/
4
"
(705 mm)
27
3
/
4
"
(705 mm)
13
3
/
4
"
(349 mm)
A. Wide opening side-swing door
B. Wide opening hamper door
Side View
Back View
30
1
/
4
"
(768 mm)
14
1
/
2
"
(368 mm)
4
3
/
4
"
(121 mm)
4"
(101 mm)
14
1
/
2
"
(368 mm)
4
3
/
4
"
(121 mm)
Steam
Non-Steam
Installation Spacing
3"*
(76 mm)
3"*
(76 mm)
24 in.
2
*
(155 cm
2
)
48 in.
2
*
(310 cm
2
)
18"*
(457 mm)
1"*
(25 mm)
1"*
(25 mm)
5
1
/
2
"*
(140 mm)
14"* max.
(356 mm)
*Required spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
■
Additional spacing should be considered for ease of installation
and servicing.
■
Additional clearances might be required for wall, door, and floor
moldings.
■
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
■