  • Whirlpool WGD49STBW | Dimension Guide - Page 1
    Dryer PRODUCT MODEL NUMBERS WGD49STB Side View 223/4" (578 mm) 273/4" (705 mm) 133/4" (349 mm) 273/4" (705 mm) 1/2" (13 mm) NOTE: Leveling legs should be 1/2" (13 mm) (to match height of 3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height of 3.8 cu. ft. capacity washer). Installation
  • Whirlpool WGD49STBW | Dimension Guide - Page 2
    and servicing. ■■ Additional clearances might be required for wall, door, and floor moldings. ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. ■■ For closet installation, with a door, minimum ventilation openings in the top and bottom
  • Whirlpool WGD49STBW | Dimension Guide - Page 3
    larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15
  • 1
  • 2
  • 3

Gas Dryer
PRODUCT MODEL NUMBERS
W10646607A
12/2014
WGD49STB
29" Wide Models Dryer Dimensions
Front View
NOTE:
Leveling legs should be 1/2" (13 mm) (to match height of
3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height of
3.8 cu. ft. capacity washer).
29"
(737 mm)
43
3
/
8
"
(1102 mm)
1
/
2
"
(13 mm)
A
B
22
3
/
4
"
(578 mm)
27
3
/
4
"
(705 mm)
27
3
/
4
"
(705 mm)
13
3
/
4
"
(349 mm)
A. Wide opening side-swing door
B. Wide opening hamper door
Side View
Back View
30
1
/
4
"
(768 mm)
14
1
/
2
"
(368 mm)
4
3
/
4
"
(121 mm)
4"
(101 mm)
14
1
/
2
"
(368 mm)
4
3
/
4
"
(121 mm)
Steam
Non-Steam
Installation Spacing
3"*
(76 mm)
3"*
(76 mm)
24 in.
2
*
(155 cm
2
)
48 in.
2
*
(310 cm
2
)
18"*
(457 mm)
1"*
(25 mm)
1"*
(25 mm)
5
1
/
2
"*
(140 mm)
14"* max.
(356 mm)
*Required spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of installation
and servicing.
Additional clearances might be required for wall, door, and floor
moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.