Whirlpool WGD49STBW Dimension Guide - Page 3
Venting Requirements, Installation Requirements - gas dryer
View all Whirlpool WGD49STBW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended. WATER (STEAM MODELS ONLY) REQUIREMENTS The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result. VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. Exhaust hoods: Recommended Styles: Determine vent length and elbows needed for best drying performance: ■■ Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in Vent System Chart. Exhaust systems longer than those specified will: ■■ Shorten life of dryer. ■■ Reduce performance, resulting in longer drying times and increased energy usage. The "Vent System Chart" provides venting requirements that will help achieve best drying performance. Louvered Hood Acceptable Style: Box Hood Angled Hood Determine vent path: ■■ Select route that will provide straightest and most direct path outdoors. ■■ Plan installation to use fewest number of elbows and turns. ■■ When using elbows or making turns, allow as much room as possible. ■■ Bend vent gradually to avoid kinking. ■■ Use as few 90° turns as possible. Number of 90° turns or elbows 0 1 2 3 4 Vent System Chart Type of vent Box/louvered hoods Angled hoods Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal 64 ft. (20 m) 54 ft. (16.5 m) 44 ft. (13.4 m) 35 ft. (10.7 m) 27 ft. (8.2 m) 58 ft. (17.7 m) 48 ft. (14.6 m) 38 ft. (11.6 m) 29 ft. (8.8 m) 21 ft. (6.4 m) NOTE: Side and bottom exhaust installations for 27" wide models have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart. Vent System Chart (Long Vent Models Only) Number of 90° turns or elbows 0 1 2 3 4 5 Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered, or Angled hoods 120 ft. (36.6 m) 110 ft. (33.5 m) 100 ft. (30.5 m) 90 ft. (27.4 m) 80 ft. (24.4 m) 70 ft. (21.3 m) Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.