Connect Vent, Level Dryer
View all Whirlpool WGD560LH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
5. Attach long hose to dryer fill valve and tighten coupling Connect Vent 1. Connect vent to exhaust outlet Using a 4" (102 mm) clamp, connect the vent to exhaust outlet in the dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp. 2. Move dryer to final location If applicable, remove protective cap from water inlet valve. Attach other end of long hose to fill valve on dryer back panel. Screw on coupling by hand until it is seated on fill valve connector. Using pliers, tighten the couplings an additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupling can result. 6. Turn on cold water faucet Check that the water faucet is turned on. 7. Check for leaks Move dryer to final location. Avoid crushing or kinking vent. After dryer is in place, remove corner posts and cardboard from under dryer. Level Dryer 1. Level Dryer Check for leaks around "Y" connector, faucets, and hoses. Check levelness of dryer from side to side. Repeat from front to back. NOTE: The dryer must be level for the moisture-sensing system to operate correctly. 16